Activated Charcoal Filter; Replace The Filter; Light Replacement - Electrolux EFG60750 Manual Del Usario

Ocultar thumbs Ver también para EFG60750:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
14 electrolux

aCTIvaTED ChaRCoaL fILTER

(RECIRCULaTIoN vERSIoN)
The filter is not washable and cannot be
regenerated. It must be replaced when
led S1 flashes or at least every 4 months.
EN
The alarm signal will only light up when
the extractor motor is switched on.
alarm signal activation
• In Recirculation version Hoods, the
Filter saturation alarm can be enabled
on installation or at a later date. Turn
the Lights and the suction Motor off.
• Disconnect the Hood using the Main
switch or the double-pole switch on
the mains power supply.
• Restore the connection by pressing
and holding T1.
• Release the button. All five LEDs are
turned on.
• Within 3 seconds press T1 until LEDs
T1 and T4 flash in confirmation:
-LED flashes twice - Activated char-
coal filter saturation alarm ENa-
BLED.
-LED flashes once - Activated char-
coal filter saturation alarm DISa-
BLED.
Maintenance
Reset the alarm signal
• Switch off the lights and extractor
motor.
• Press button T3 for at least 3 sec-
onds, until the leds start to flash.

Replace the filter

• Pull the Comfort Panel to open it.
• Remove the metal grease filters
• Remove the saturated activated
carbon filter by releasing the fixing
hooks
• Fit the new filter by hooking it into its
seating
• Replace the metal grease filters.

LIghT REPLaCEMENT

20 W halogen light.
• Extract the lamp from the lamp holder
by pulling gently.
• Replace with another of the same
type, making sure that the two pins
are properly inserted in the lamp
holder socket holes.
Tabla de contenido
loading

Este manual también es adecuado para:

Efg90750

Tabla de contenido