14 electrolux
aCTIvaTED ChaRCoaL fILTER
(RECIRCULaTIoN vERSIoN)
The filter is not washable and cannot be
regenerated. It must be replaced when
led S1 flashes or at least every 4 months.
EN
The alarm signal will only light up when
the extractor motor is switched on.
alarm signal activation
• In Recirculation version Hoods, the
Filter saturation alarm can be enabled
on installation or at a later date. Turn
the Lights and the suction Motor off.
• Disconnect the Hood using the Main
switch or the double-pole switch on
the mains power supply.
• Restore the connection by pressing
and holding T1.
• Release the button. All five LEDs are
turned on.
• Within 3 seconds press T1 until LEDs
T1 and T4 flash in confirmation:
-LED flashes twice - Activated char-
coal filter saturation alarm ENa-
BLED.
-LED flashes once - Activated char-
coal filter saturation alarm DISa-
BLED.
Maintenance
Reset the alarm signal
• Switch off the lights and extractor
motor.
• Press button T3 for at least 3 sec-
onds, until the leds start to flash.
Replace the filter
• Pull the Comfort Panel to open it.
• Remove the metal grease filters
• Remove the saturated activated
carbon filter by releasing the fixing
hooks
• Fit the new filter by hooking it into its
seating
• Replace the metal grease filters.
LIghT REPLaCEMENT
20 W halogen light.
• Extract the lamp from the lamp holder
by pulling gently.
• Replace with another of the same
type, making sure that the two pins
are properly inserted in the lamp
holder socket holes.