TROUBLESHOOTING, CAUSES, SOLUTIONS

Error message

No light switches on
Test light illuminated green, yellow or
red during the day
Orange or red charge indicator
High voltage alarm in your vehicle,
boat,
34/55
Causes
The solar charge controller
needs the battery voltage to
be higher than 6V in order to
turn on when being
connected to the battery
Battery polarity reversal
Battery connection problem
(cables, terminals...)
Defective battery
Solar panel disconnected, not
properly connected, or short
circuit
Normal functioning: The
panel's voltage is lower than
the battery's voltage or too
low solar radiation.
One or several cells of your
panel are covered up.
Battery discharged
Battery deeply discharged.
Using Liquid Recond Mode
www.uniteck.fr
Solution
Check the battery's voltage,
recharge it if necessary.
Check the connections.
Replace your battery,
following the order of
disconnection and connection
(refer to installation and
connection passage).
Check the connections
(polarity and connection).
The
panel
will
charging as soon as the
panel voltage exceeds the
battery voltage.
Check if your solar panel is
clean and make sure none of
the cells are covered.
With a standard charge, the
light turns green as soon as
the battery is charged.
Change settings of the alarm
Set your product to Liquid
mode (without Recond)
resume