when main counter = preset
value 2
Automatic reset to zero when
main counter = preset value 2
Output 3 active when main
counter > preset value 3
Total counter counts all the count
pulses from the main counter
Output 1 resp. 4 active when
total counter > preset value 1
resp. 4
Manual Reset sets both counters
to zero
Electronic reset only sets the
main counter to zero
Submenu for configuration
Submenu for matching the time
ranges and display
Unit of time
Unit of time: seconds
Decimal point setting determines
the resolution
Unit of time: minutes
Decimal point setting determines
the resolution
Unit of time: hours
Decimal point setting determines
the resolution
Unit of time: Hrs. Min. Sec.
Decimal point setting (Resolution)
Decimal place
(determines the resolution)
0
0.0
0.00
0.000
Set value
Set value can be programmed
from 000000 to 999999
A previously programmed
decimal point will be displayed
Display colour (for device 6.924.x103.xxC]
Display colour
upper line
lower line
www.kuebler.com
no decimal place
1 decimal place
2 decimal places
3 decimal places
red
red
Display colour
upper line
lower line
7.8.6.4 Submenu for reset mode
Setting the reset mode
Manual reset (with red key) and
electrical reset (reset input)
No reset possible (red key and
reset input inhibited)
Only electrical reset possible
(reset input)
Only manual reset possible (red
key)
7.8.6.5 Submenu for Preset 1
Submenu for turning preset 1
ON/OFF
ADD mode output operations:
permanent signal at Output 1,
becomes active when count >
Preset 1
SUB mode output operations:
permanent signal at Output 1,
becomes active when count <
Preset 1
ADD mode output operations:
permanent signal at Output 1,
becomes passive when count >
Preset 1
SUB mode output operations:
permanent signal at Output 1,
becomes passive when count <
Preset 1
red
green
Seite 13