Communication
CAN
Baud Rates
Default Baud Rates 250 kbit/s
Protocol
NOTES:
1. No HAZARDOUS LIVE parts are present in the equipment. Terminals are
rated to 32 Vdc maximum.
2. Recommended supply voltage 12 Vdc or 24 Vdc with negative to earth.
6Vdc protection for engine cranking events.
3. Use twisted or twisted shielded-pair cable for CAN per the applicable
standard.
Environmental
Operating
Temperature
Storage
Temperature
EMC/EMI
www.sunhydraulics.com
2.0B (Maximum voltage + 32 Vdc)
125 kbit/s, 250 kbit/s, 500 kbit/s, 1 Mbit/s
SAE J1939
-40°C to +85°C
(-40°F to +185°F)
-60°C to +120°C
(-76°F to +248°F)
EN 55024, EN 55032, EN 13309, EN/ISO 14982, ISO 13766,
ISO 16750-2, J1113-4/11/12/13/26, ISO 1142-2/10,
CISPR 25, FCC 15B, ICES-003, UNECE Reg 10.5, EN
61326-1:2013, EN 301 489-1 V2.2.0, EN 301 489-17, EN 12895
© 2017 Sun Hydraulics Corporation
Pub.#999-901-853 November 2017
Vibration
33.3 Hz 6.8g Peak
(Spec: S-367 Section 11.0)
Shock
49g Peak (Spec: S-367
Section 12.0)
EN
05