Technical Specifications - Perry TE526 Manual Del Usuario

Termostato digital de superficie
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

1 - TECHNICAL SPECIFICATIONS

Power supply voltage:
DATI TECNICI
DATI TECNICI
Autonomy of battery-powered model:
Time remaining from when the low
DATI TECNICI
battery
symbol blinks on the display:
Backlight:
Software:
Rated impulse voltage:
Type of action, disconnection and device:
Type of output:
Device connection (load):
Input for telephone programmer connection:
Cross-section of wires to terminals:
Adjustable Levels of Temperature:
Room temperature display field:
Room temperature resolution:
COMFORT and REDUCTION T Set
temperature setting adjustment field:
Temperature setting resolution:
Temperature reading tolerance:
Correcting the detected room temperature (Offset):
Antifreeze temperature:
Type of temperature adjustment:
- ON/OFF with differential switch
- Proportional with control period
Thermal gradient:
Degree of protection:
Class of insulation:
Pollution rating:
Operating temperature limits:
Storing temperature limits:
Reference regulations for CE markings:
2 x 1,5V
Alkaline
stilo batteries type AA (LR6)
Approx. 2 years
Approx. 1 month
Set to 5 seconds from when the last button is released
Class A
4 kV
1/B/ Electronic
voltage free relay with NO / COM / NC changeover contact
max 5 (3) A / 250V~
2 or 3 conductors
for a voltage free NO contact
2
2
1,5 mm ÷ 2,5 mm
COMFORT / REDUCTION (energy saving) / ANTI-FREEZE (OFF)
0 ÷ +37,7°C
0,1°C
+5 °C to +37,0 °C(restrictable)
0,1 °C
± 0,5 °C
adjustable -2°C ÷ +2°C (default 0,0 °C)
+4 °C to + 12 °C (adjustable or excludable set) (default 4 °C)
adjustable from 0,2 °C to 1,2°C (default 0,5 °C)
adjustable from 7 to 20 minutes (default 10 minutes)
1°K / 15 min
IP 30
II
normal
0°C ÷ +45°C
-10°C ÷ +60°C
LVD - EMC
EN60730-1 EN60730-2-9
EN
EN
21