MOUNT THE GLASS RANGE HOOD
(Continued)
4. Remove the top duct cover bracket from the wall.
5. Align the top edge of the duct cover bracket with
the top edge of the recirculation duct mounting
bracket that is attached to the recirculation duct.
Align the center notches of each bracket. Place
both brackets back onto the wall in the previous
position. Install the 2 mounting screws into the
anchors and securely tighten.
Ceiling
Top Duct
Cover
Bracket
6. Attach the
CHARCOAL FILTER
(not included).

ELECTRICAL CONNECTION

1. Remove the cover from the field wiring
compartment. Feed the Power Supply Cable
through the hole in the compartment.
2. Connect the Power Supply Cable to the range
hood junction box through the hole that was
drilled in the "Preparing the Wall" section on
page 6. Attach the White lead of the power
supply (A) to the White lead of the range hood
(D) with a wire nut. Attach the Black lead of the
power supply (B) to the Black lead of the range
hood (C) with a wire nut. Connect the Green
(E) (Green
and Yellow)
ground
wire under
the Green
grounding
screw.
E
3. Secure the
junction
box to the
wall using
2 dry wall self-tapping screws into the two
diagonal holes in the junction box. Reattach
the field wiring compartment cover.
8
Installation Instructions
Recirculation
Duct Bracket
B
C
E
D
A
Secure
junction
box to the
wall using
these
holes.
FINISH THE INSTALLATION
1. Ducted installation only: Connect the house
ducting to the damper on the hood body. Seal
all connections with duct tape.
2. For ducted and recirculation installation:
Install the upper duct cover. Slightly spread the
sides of the cover apart and hook them behind
the duct cover mounting brackets. Attach the
cover to the brackets with 4 duct cover screws.
NOTE: Depending on the ceiling height and
hood install height, the upper duct cover can
be installed with the exhaust vents on the top
towards the ceiling, or flip the duct cover and
hide the exhaust vents under the lower duct
cover.
3. Install the lower duct cover. Slightly spread the
sides of the cover apart and hook them behind
the upper duct cover and the wall. Slide the
lower duct cover down to fit securely into the
top of the range hood.
4. Finish attaching the lower duct cover to the
chimney of the vent hood with 2 duct cover
screws into holes on both sides of the cover.
5. Reinstall the metal grease filter to the vent
hood.
6. Turn the power supply on. Turn on blower
and light. If the rangehood does not operate,
check that the circuit breaker is not tripped
or the house fuse blown. If the unit still does
not operate, disconnect the power supply and
check that the wiring connections have been
made properly.