Do not exceed the amperage ratings of the extension cord. Undersized
extension cords create excessive drops in voltage, causing the electric motor
to generate excess heat. This results in inefficient motor operation and
premature motor failure and will void the warranty.
Three-Conductor Heavy Duty Extension Cord Requirements
Cord
Length
0–50 ft
(0–15 m)
50–100 ft
(15–30 m)
The cooler must be placed on level ground to operate correctly. Evaporative
coolers create an oval-shaped air pattern. Obstacles such as racks and
workbenches may interfere with airflow. Position the cooler so that interruption
of the air pattern is minimized. Multiple coolers may be required to cover larger
areas.
There are three major factors to consider when determining where to place the
cooler.
1. Fresh Air Supply. The inlet (mesh sides) requires a constant, uninterrupted
supply of fresh air for maximum performance. A distance of 3 ft (0.9 m)
of clear space to any obstructions at the rear or inlet side of the cooler is
recommended.
2. Discharge Airflow. The cool air discharged from the cooler should be free from
obstruction to promote air circulation in order to maximize the cooling zone.
3. Ventilation. Adequate ventilation is needed to ensure the cooler does not
recirculate air that has already been through the evaporative cooling process.
Filling the cooler with water
Once the cooler has been connected to a water source, turn the water source on
to fill the cooler with water. The float valve will shut off the water flow when the
sump is full.
WWW.BIGASSFANS.COM
CAUTION
16 GA
13 A
10 A
OPERATION
© 2020 DELTA T LLC
Cord Size
14 GA
18 A
13 A
Table 2: Cord Size Requirements
ALL RIGHTS RESERVED.
12 GA
25 A
18 A
10 GA
30 A
25 A
3