Technical Data - AERMEC NRA 0800 Manual Tecnico

Enfriadoras y bombas de calor aire agua y motocondensadores con compresores scroll
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MOD.
ROMEO
TP1
NRA HL
0800
std.
0900
std.
1000
std.
1250
std.
1400
std.
1500
std.
1650
std.
1800
std.
NRA C
0800
• (x2)
0900
• (x2)
1000
• (x2)
1250
• (x2)
1400
• (x2)
1500
• (x2)
1650
• (x2)
1800
• (x2)
NRA LC
0800
• (x2)
0900
• (x2)
1000
• (x2)
1250
• (x2)
1400
• (x2)
1500
• (x2)
1650
• (x2)
1800
• (x2)
KEY
DRE - RIF It must be factory-mounted
S.a = Without storage tank
C.a With storage tank
NOMINAL REFERENCE
5. 1
CONDITIONS
The technical data is calculated as follows
Cooling mode
- Temperature water inlet
- Temperature of processed water
- Ambient air temperature
- ∆t
Heating mode
- Temperature of processed water 50 °C
- Ambient air temperature
- ∆t
Sound Power
Aermec determines the value of sound
power on the basis of measurements per-
formed in compliance with regulation 9614,
in respect with that requested by Eurovent
certification.
Sound Pressure
(1)
Sound pressure in free field on a reflective
surface (factor of directionality Q=2), at 10
metres from the external surface of the
unit, using the parallel expansion method
(box-method, ISO 3744)
8
DRE
AER485
25 (x4)
25 (x2) - 30 (x2)
30 (x4)
38 (x4)
38 (x2) - 31 (x3)
30 (x6)
38 (x3) - 31 (x3)
38 (x6)
25 (x4)
25 (x2) - 30 (x2)
30 (x4)
38 (x4)
38 (x2) - 31 (x3)
30 (x6)
38 (x3) - 31 (x3)
38 (x6)
25 (x4)
25 (x2) - 30 (x2)
30 (x4)
38 (x4)
38 (x2) - 31 (x3)
30 (x6)
38 (x3) - 31 (x3)
38 (x6)
NOTE
The numbers in parenthesis indicate the
necessary quantity

TECHNICAL DATA

5
NOTE
- The noise data refer to configuration without
pump.
- For heat pumps the data refers to functioning
in cooling mode
E.S.E.E.R.
12 °C
There is a growing awareness in Europe
7 °C
as well that attention needs to be paid
35 °C
to the electricity consumed by air condi-
5°C
tioning machines. For many years now in
the United States talk has not just been
about efficiency in the plan conditions, but
b.s. 7 °C
an assessment index is used that takes
b.u. 6 °C
account of the marginal operation of the
5°C
unit under plan conditions and the greater
use with partial loads with external air that
is less than that planned and in conditions
of compressor capacity control. In Europe
the proposed EECCAC (Energy Efficiency
ESEER = (3xEER100%+33xEER75%+41xEER50%+23xEER25%) / 100
Acqua uscita evaporatore
∆T a pieno carico
Carico
Temperatura aria esterna
PGS
GP
DCPX
RIF
260
64
std.
260
std.
74
260
std.
84
350
84
std.
350
std.
85
350
std.
86
500
86
std.
500
std.
86
260
29
64
260
29
74
260
29
84
350
30
84
350
30
85
350
30
86
500
30
86
500
30
86
260
64
std.
260
std.
74
260
std.
84
350
84
std.
350
std.
85
350
86
std.
500
86
std.
500
std.
86
AVX
S.a
C.a.
P1/P2/P3/P4
151
152
151
151
152
151
151
152
151
153
154
153
153
154
153
153
154
153
604
602
P1-P3=605/P2-P4=606
604
602
P1-P3=605/P2-P4=606
151
152
151
151
152
151
151
152
151
153
154
153
153
154
153
153
154
153
151
152
151
151
152
151
151
152
151
153
154
153
153
154
153
153
154
153
and Certification of Central Air Conditioner)
has been adopted, the ESEER (European
Seasonal Energy Efficiency Ratio), that has
the purpose of being able to compare the
chillers with each other.
After estimating the total energy required
by the system during summer manage-
ment (kW/h), the seasonal electrical ener-
gy consumption can be deduced with this
formula:
Input energy = Required energy
Efficiency index
The actual energy calculation can be obtai-
ned, more accurately, by considering:
1. The load profile with external tempera-
ture
2. The climatic profile
3. The total number of hours
With this data, every consultant or desi-
gner will be able to his or her evaluations.
7 °C
5 °C
100%
75%
50%
25%
35°C
30°C
25°C
20°C