Safety instructions
Correct installation
Check the manufacturer's speciications
for the cooker to determine whether an
extractor hood can be operated over it.
If the manufacturer of the cooker has not
speciied any signiicant safety distances, the
following minimum distances apply
– 550 mm between electric hob and the
lower edge of the extractor hood,
– 650 mm between gas hob (upper edge of
pan support) and the lower edge of the
extractor hood
(see ig. 1, page 2).
If various cookers are used, the greatest
NOTE: It is recommended to switch on the
blower when you start cooking and not to
switch it of again until several minutes after
you have inished cooking. In this way the
kitchen fumes are removed most efectively.
RISK OF INJURY
from hot cooking utensils.
When operating the extractor hood, do not
reach over hot cooking utensils.
On/Of
Fan run-on
Intermittent ventilation
Switch back fan
Display fan settings
Increase fan speed
Intensive setting
Light On/Of
Setting the fan
# button to switch on the
Press the
appliance. The fan starts at setting 2.
Increase fan setting by pressing the +
button and reduce it by pressing the –
button.
12
indicated distance applies.
The width of the extractor hood must
correspond to the width of the cooking area.
The extractor hood must not be installed
over a solid fuel heating appliance which
may be a ire risk (e.g. lying sparks) unless
the heating appliance has a closed, non-
detachable cover and the country-speciic
regulations are observed. This restriction
does not apply to gas cookers and gas hobs.
To avoid damaging the hob, cover it
when installing the extractor hood.
Intensive setting
You can use the Intensive setting for
particularly strong odour and fume
generation.
– approx. 5 minutes
Y
– approx. 10 minutes
Z
Press the
ç button. Z is indicated on
the display. Press the – button to reduce the
setting to
Y .
The duration is limited. Then the fan is
automatically reduced to a lower setting.
You can reduce the setting any time by
pressing the
X button.
Fan run-on
n button.
Press the
The fan runs for 6 min at Setting 1.
Then the fan switches of automatically.
To change the run-on times, press the +
or – button.
Display ] approx. 3 minutes
Display \ approx. 6 minutes
Display [ approx. 9 minutes.
Intermittent ventilation
n button 2x. The fan runs
Press the
approx. 5 min per hour.
To switch of intermittent ventilation,
# button.
press the
Operation
Light
The light can be switched on and of
independently of the fan.
< .
Press button
Setting the brightness
Hold down the
brightness is obtained.
LED lights
Defective LED lights may be replaced by
the manufacturer, or a qualiied technician
(electrician) only.
RISK OF INJURY
Do not look directly into the switched on
LED lights for longer than 100 seconds.
Acoustic signal
When a button is pressed, an
acknowledgement signal sounds.
Switching of the acoustic signal
When the fan is switched of, simultaneously
hold down buttons
3 seconds.
A acknowledgement signal sounds.
Switching on the acoustic signal
Repeat the "Switch of acoustic signal"
process.
< button until the required
# and + for approx.