Technical data

Weight (kg) Weight (lb)
CP3019-12AC
0.51
CP3019-12AC
0.51
CNOMO
CP3019-20
0.38
CP3019-20
0.38
CNOMO
CP3019-20AC
0.51
CP3019-20AC
0.51
CNOMO
Noise and vibration
Sound pres-
sure level
(dB(A))
CP3019-12AC
78
CP3019-12AC
78
CNOMO
CP3019-20
74.7
CP3019-20
74
CNOMO
CP3019-20AC
82
CP3019-20AC
82
CNOMO
Declarations

EU DECLARATION OF CONFORMITY

We, CHICAGO PNEUMATIC Tool Co. LLC, 1815 Club-
house Road, Rock Hill, SC 29730, declare under our sole re-
sponsibility that the product (with name, type and serial
number, see front page) is in conformity with the following
Directive(s):
2006/42/EC (17/05/2006)
Harmonized standards applied:
EN ISO 11148-9:2012
Authorities can request relevant technical information from:
Pascal Roussy, R&D Manager, Ets Georges Renault, 38 rue
Bobby Sands, BP10273 44818 Saint Herblain, France
Saint-Herblain,
Pascal ROUSSY
Signature of issuer
4
Free
speed (rpm)
1.11
12000
1.11
12000
0.83
20000
0.83
20000
1.11
20000
1.11
20000
Vibra-
Vibration
tion (m/s²)
uncertainty
3.7
1.9
3.7
1.9
4.1
1.5
<2,5
4.3
3.4
4.3
3.4
© Chicago Pneumatic - 8940176157
Statement of use
This product is designed for removing material using abra-
sives. No other use permitted. For professional use only.
Maintenance instructions
• Follow local country environmental regulations for
safe handling and disposal of all components.
• Maintenance and repair work must be carried out by
qualified personnel using only original spare parts. Con-
tact the manufacturer or your nearest authorised dealer
for advice on technical service or if you require spare
parts.
• Always ensure that the machine is disconnected from en-
ergy source to avoid accidental operation.
• Disassemble and inspect the tool every three 3 months if
the tool is used every day. Replace damaged or worn
parts.
• To keep downtime to a minimum, the following service
kit is recommended : Tune-up kit
Disposal
• The disposal of this equipment must follow the legisla-
tion of the respective country.
• All damaged, badly worn or improperly functioning de-
vices MUST BE TAKEN OUT OF OPERATION.
• The disposal of this equipment must follow the legisla-
tion of the respective country.
• Repair only by technical maintenance staff.
Lubrication
Use an air line lubricator with SAE #10 oil, adjusted to two
(2) drops per minute.
Useful information
Website
Log in to Chicago Pneumatic: www.cp.com.
You can find information concerning our products, acces-
sories, spare parts and published matters on our website.
Country of origin
Hungary
Copyright
© Copyright 2019, CHICAGO PNEUMATIC Tool Co. LLC,
1815 Clubhouse Road, Rock Hill, SC 29730
All rights reserved. Any unauthorized use or copying of the
contents or part thereof is prohibited. This applies in particu-
lar to trademarks, model denominations, part numbers and
ANGLE DIE GRINDER
Tabla de contenido
loading

Este manual también es adecuado para:

Cp3019-20acCp3019-12ac cnomoCp3019-20 cnomoCp3019-20ac cnomo

Tabla de contenido