Initial Setup & Operation
See Fig. 1 illustration for desolder tool.
1.
Connect hand-piece to power unit output connector(s).
2.
Connect hand-piece vacuum line to the port on the main unit.
3.
Insert your selected tip (cartridge) into the hand-piece. Push the tip (cartridge) all the
way until it seats (See instructions supplied with each hand-piece).
4.
Place hand-piece(s) into associated workstand(s)
5.
Add distilled water to workstand sponge (sulfur free).
6.
Select the desired channel using the selector switch.
7.
Plug the power cord into a grounded wall socket of the rated input line voltage.
8.
To turn the unit on, push the AC power switch. The AC power LED should light up
green.
Always use tip removal pad for changing tips.
Tip Selection
Part Number
Regular
DFP-CN2
DFP-CN3
DFP-CN4
DFP-CN5
DFP-CN6
DFP-CN7
Long Reach
DFP-CNL3
DFP-CNL4
DFP-CNL5
Maintenance of Desolder Tool
To change coil assembly remove screws (Fig. 1), replace with part number MFR-HDCA.
Replace front seal part number AC-SK1 if worn.
Disposable Collection Chamber Cartridge
Replacing the Vacuum Port Filter on the MFR-PS1300
a.
Turn the filter cover anti-clockwise until it stops then pull to remove.
b.
Remove old filter (use tweezers). Insert new filter, (AC-VPF.)
c.
Reinstall filter cover, push and then turn clockwise to lock.
Vacuum
Port & Filter
Dimension A
0.64 mm
0.76 mm
1.02 mm
1.27 mm
1.52 mm
2.41 mm
0.76 mm
1.02 mm
1.27 mm
1
2
Dimension B
1.8 mm
2.0 mm
2.3 mm
2.6 mm
2.8 mm
3.6 mm
2.0 mm
2.3 mm
2.6 mm
MFR-DC10 (package of 10)
MFR-DC100 (package of 100)
6