WARNING
DO NOT USE PUMP for fuel, solvent, oil, or
anything flammable. When pumping corrosive
liquid, use extreme caution. Follow handling
instructions provided by manufacturer of the liquid.
Always wear adequate protective clothing.
Keep hands and body clear from discharge of
pump. Secure discharge hose to avoid whip
ping. Never place hands or body parts inside of
running pump or hoses.
Anchor pump to avoid walking" or equipment
movement, especially if located near ditch or
edge of open ravine, the equipment could fall in.
Keep equipment away from edge of river or lake
where it could cause the edge to collapse.
Never allow vehicles to drive over hoses. If a
hose must be positioned across a roadway, use
planking on each side of hose to allow vehicles
to pass over without obstructing or collapsing
hose.
Keep all connections air tight. Use a non col
lapsible hose on the suction side of pump. Do
not obstruct the inlet or discharge hose in
anyway. Damage to the pump may occur.
Ensure all connections on suction side of pump
are air tight.
NEVER OPERATE PUMP without strainer
connected to end of suction hose.
ALWAYS prime pump before starting the
engine. Never run pump with out priming.
CAUTION: Damage to the pump or equip
ment may occur if hoses are obstructed in
anyway.
Pump Setup

(see fig.
)
Ê
Total head
. . . . . . . . . . . . . . . . .
Ë
Suction lift
. . . . . . . . . . . .
8 m (25 ft) maximum.
For better performance, keep suction lift at a minimum.
CAUTION: Do not exceed suction lift. If
suction lift is beyond maximum, pump may
overheat before liquid reaches casing. This
condition may cause damage to the seal. Use
shortest suction lift possible.
Prime pump before every use. Remove plug
and fill cavity with water only.
Keep strainer out of sand or silt, place in
Í
Î
bucket
or on stones
.
Ï
Keep all connections
air tight.
Ð
Always use strainer
with suction hose.

Before Starting

(see fig.
Ê
Check oil level. Oil should be at FULL.
See OIL RECOMMENDATIONS.
Ë
Add fuel.
See FUEL RECOMMENDATIONS.
Ì
Move choke lever to close.
Í
Open fuel shut off valve.
Î
Move throttle lever to RUN.
Ï
Push stop switch to ON position
(if equipped).
Starting

(see fig.
)
Pull rope handle to start engine
As engine warms up, move choke
Ë
lever to open
.
When engine starts, operate in FAST position.
Stopping

(see fig.
)
CAUTION
Do not move choke control to CHOKE position
stop engine. Backfire or engine damage may occur.
Move throttle lever to SLOW or STOP
Push stop switch to OFF position
Í
Close fuel shut off valve
.

Engine Specifications

Armature air gap
.
0.25 - 0.36 mm (0.010 - 0.014 in.)
Spark plug gap
. . . . . . . . . . . . .
0.76 mm (0.030 in.)
Valve clearance, with valve springs installed, and piston
6 mm (1/4 in.) past top dead center (check when engine is
cold):
Intake
. . . . . . .
0.10 - 0.15 mm (0.004 - 0.006 in.)
Exhaust
. . . . . .
0.23 - 0.28 mm (0.009 - 0.011 in.)
3

Oil Recommendations

Equipment is shipped from Briggs & Stratton
32 m (106 ft).
without oil. Before starting engine, fill with oil. Do
not over fill.
Use a high quality detergent oil classified For Service
SF, SG, SH, SJ" or higher. Use no special additives with
recommended oils. Do not mix oil with gasoline.
Note:
GF 2, API certification mark and API ser
vice symbol (shown at left) with SJ/CF
Ì
ENERGY CONSERVING" or higher, is an
acceptable oil at all temperatures. Use of
synthetic oil does not alter required oil
change intervals.
Use recommended SAE viscosity grade oil per starting
temperature according to chart. (see fig.
*
Air cooled engines run hotter than automotive

)
engines. The use of non synthetic multi viscosity
oils (5W 30, 10W 30, etc.)in temperatures above
40° F (4° C) will result in higher than normal oil
consumption. When using a multi viscosity oil,
check oil level more frequently.
** SAE 30 oil, if used below 40° F (4° C), will result
in hard starting and possible engine bore
damage due to inadequate lubrication.
Check oil level. (see fig.
Oil Capacity: Models 110000, 120000 is about 20 oz. or
0.6 liter.
Place engine level and clean around oil fill.
Remove oil fill plug
Ê
.
Oil should be full to overflowing
Tighten oil fill plug firmly before starting engine.

Fuel Recommendations

Use clean, fresh, lead free gasoline with a minimum of
85 octane. Leaded gasoline may be used if it is
commercially available and if unleaded is unavailable.
This engine is certified to operate on gasoline. Exhaust
Emission Control System: EM (Engine Modifications).
Do not use gasoline which contains Methanol.
Ê
to
Do not mix oil with gasoline.
Fill tank to approximately 1 1/2 inches below top of
Ë
position
.
neck to allow for fuel expansion.
Ì
.
Synthetic oil meeting ILSAC

)

)
Ê
.
Ë
.