the motor (turn clockwise to increase torque).
5 - After other10 seconds (6 for FAST operator) motor working, the low
speed control is automatically activated (DIP9 OFF). Set the motor
low speed by the LOW SPEED Trimmer to select the gate leaf low
speed in approaching.
6 - Press and hold the PROG.Button to close completely the gate. Turn
DIP1 to OFF, the RED led DL1 will stop blinking.
During Point C procedure, safety devices (photocells and safety
strip), stop button and encoder input are not active.
(#) In Point D and Point E procedures, all of them will be active, so
they must be properly installed and connected to the control board. Any
changing of the safety devices input state, will stop the Point D and
Point E procedure that must be repeated from the beginning.
POINT D
- PROGRAMMING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, LED DL1 starts blinking
3 - Press PROG.Button, motor opens.
4 - Once reached the open position, the open limit switch will cut out
motor and the gate travelling will be stored. The gap of time between
now (stop of motor) and the next pressing of the PROG.Button
(see step 5 below) will be then stored as waiting time for Automatic
Closing feature.
5 - Press PROG.Button, gate closes and the Automatic Closing time
is stored (see DIP3 function to enable or disable the Automatic
Closing feature).
6 - The LED DL1 will turn OFF, signalling exit from the Point D
procedure.
Closing of the gate will be carried out at normal speed and only
on approaching total closing at low speed (depending on the
adjustment of LOW SPEED trimmer).
7 - When the gate leaf reaches the close limit switch plate, the motor
stops.
8 - Turn DIP2 to OFF position.
IN CASE OF PLUS OPERATORS EQUIPPED WITH ENCODER,
THE DIP7 MUST BE TURNED ON DURING THE PROGRAMMING
PROCEDURES.
POINT E
- PROGRAMMING
OPENING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly
3 - Immediately, turn also DIP1 to ON position, the LED DL1 starts
blinking slowly
4 - Press the pedestrian pushbutton PED.Button, the gate opens
5 - When the gate leaf is opened enough for the pedestrian crossing,
press the pedestrian pushbutton PED.Button to stop the travel
(thus defining the opening stroke of the motor). The gap of time
between now (stop of the motor) and the next pressing of the
PROG.Button (see step 6 below) will be stored as waiting time for
Pedestrian Automatic Closing feature.
6 - Press the pedestrian pushbutton PED.Button, gate closes and
the Pedestrian Automatic Closing time is stored (see DIP3 function
to enable or disable the Automatic Closing feature).
7 - Turn DIP1 to OFF position
8 - Turn DIP2 to OFF position
F
UNCTIONING OF CONTROL ACCESSORIES
ATTENTION: ONLY IMPULSIVE COMMANDS HAVE TO BE
CONNECTED.
Make sure that any other type of command accessories (e.g.
mass detectors) used on the installation are set in the IMPULSIVE
mode, otherwise, the gate will be operated even without the
protection of the safety devices.
OF
PEDESTRIAN
24
24
STEP BY STEP or AUTOMATIC commands (K BUTT, PED.Button)
DIP5 - ON The K BUTT and PED.Button perform the step by step
cyclic command open-stop-close-open-stop-etc.
DIP5 - OFF The K BUTT and PED.Button perform the automatic
command:
- the open command, if pressed with the gate completely
closed
- the close command, if pressed with the gate completely
opened
- no effect, if pressed during the gate opening
- the gate re-open, if pressed while the gate is closing
The K BUTT opens the gate completely, whereas the PED.Button
opens the gate partially as described in Point E.
STEP BY STEP or AUTOMATIC commands (radio command)
DIP4 - ON The RADIO COMMAND perform the step by step cyclic
command open-stop-close-open-stop-etc.
DIP4 - OFF The RADIO COMMAND perform the automatic command:
- the open command, if pressed with the gate completely
closed
- the close command, if pressed with the gate completely
opened
- no effect, if pressed during the gate opening
- the gate re-open, if pressed while the gate is closing
OPEN BUTTON (COM-OPEN)
The button controls the opening movement when the gate is stationary.
If activated while closing, it reopens the gate.
CLOCK FUNCTION
If you want the Clock Function must request S1 with firmware
03.
ATTENTION: A CLOCK CONNECTED TO S1 with fw 04 or more
ACTIVATES THE OPENING MOVEMENT OF THE GATE WITHOUT
HAVING THE PROTECTION OF THE SAFETY DEVICES!
The Clock Function permits to keep the gate opened even if, for
example, the Automatic Closing is enabled (DIP3 ON) or somebody
commands the gate closing.
It is useful during rush hours, when traffic is heavy and the flow is slow
(e.g. entrance/exit of employees, emergencies in residential areas or
car parks and, temporarily, for removal vans) and it's necessary to keep
the gate opened.
CLOCK FUNCTION APPLICATION
It is necessary to request a S1 control panel with firmware 03.
It can be done by connecting a switch and/or a daily/weekly clock
either in parallel to the OPEN button or instead of the OPEN button.
When the control board receives this command, the gate will open and
by keeping this contact closed for all the time of the gate opening, the
Clock Function is automatically activated. In fact, once reached the
open position, the gate will remain opened and all of the control board
functions are blocked. Only when OPEN contact is released, the control
board functions are re-activated and the gate will close immediately.
PEDESTRIAN command (PED.Button - COM)
This command is useful to open the gate partially, just enough, for
example, to permit a pedestrian crossing, see Point E procedure.
From the Pedestrian opening position the Automatic Closing can be
enabled or disabled with DIP3. From the Pedestrian opening position,
the gate can be completely opened by the OPEN or by the K BUTT
button or by the RADIO button.
AUTOMATIC CLOSING (from the COMPLETE open position)
The Automatic Closing from the complete open position can be enabled
turning ON the DIP3.
The maximum gap of time that can be programmed is 5 minutes (see
Point D).