Testing And Calibration - Toto TBV02405U Manual De Instalación Y Del Propietario

Válvula termostática de mezcla
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Adjusting the Temperature
To decrease the temperature, turn the
temperature control handle clockwise.
To increase the temperature, turn the
temperature control handle counter-
clockwise.
A safety button is provided to
prevent hot water from spraying out
due to misuse. If the desired water
temperature is above 104ºF(40ºC),
please turn the handle while pressing
down on the safety button.
Adjusting the Maximum Outlet
Temperature
Align the safety button on the
temperature control handle with "104"
on the trim surface.
Turn the water on and confirm if the
outlet temperature is 104ºF(40ºC).
If not, please adjust the water outlet temperature by
following the steps below:
1. To decrease temperature:
Remove handle cap. Remove screw and pull handle
slowly. Turn handle counter-clockwise one notch
and reinstall onto cartridge.
To increase temperature:
Remove handle cap. Remove screw and pull
handle slowly. Turn handle clockwise one notch and
reinstall onto cartridge.
2. Secure handle with screw and install handle cap.
3. Check water temperature.
** Repeat steps 1-3 if necessary.

TESTING AND CALIBRATION

10
Hot water
side
Safety button
Temperature control handle
Temperature
control handle
Small screw
Handle cap
Cold water side