Use
Keep work area free from obstructions, trip hazards, and spills which
could impair the safe operation of the fall-rescue
Do not open the confined space access cover before complete
installation of the anchorage connector and all other system
components.
3.2.
Pre-Use Inspection
Inspect the confined space system to verify that it is in serviceable
condition. Examine every inch of the confined space system for severe
wear, missing or broken elements, corrosion, or other damage. Do not
use the confined space system if inspection reveals an unsafe condition.
3.3.
Pre-Assembly
Always work in teams of at least two (2) people (one (1) attendant and
one (1) confined space worker) who are qualified and trained on the
confined space system.
(1.) Remove all components and parts from bags, boxes, or shipping
(2.) Remove the pin from the T-bar leg assembly (A) and rotate to
US
US
14
container and set on ground. Make sure that components are in
good working condition.
horizontal position. Lock the T-bar leg assembly with the pin (B).
Fig. 5
Step 2A
MSA/XTIRPA™ Pole Hoist System
Caution
system.
Fig. 6
Step 2B