Product Conformity - DEA SYSTEM GHOST 200 Instrucciones De Uso Y Advertencias

Operador electromecánico enterrado para puertas de hoja batiente
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

GHOST 200
Underground electro-mechanical operator for swing gates
Operating instructions and warnings
INDEX
Declaration by manifacturer ..........................1
OVERVIEW . ......................................................7
1 PRODUCT CONFORMITY . .................................7
2 RESIDUAL RISK WARNINGS ............................7
3 MODELS AND CONTENTS OF THE PACKAGE . ..8
4 OPERATING INSTRUCTIONS ...........................8
4.1 Product description . ...............................8
4.2 Technical data . .......................................8
4.3 Labelling information . ...........................8
4.4 Appropriate conditions of use ..............8
4.5 Instructions for risk-free operation .......9
4.5.1 Transport – 9
4.5.2 Installation, assembly
and disassembly – 9
4.5.3 Starting – 9
4.5.4 Use – 9
4.5.5 Adjustment – 10
4.5.6 Maintenance and repair – 10
4.6 Training ...............................................10
4.7 Inappropriate use . ...............................10
5 SPARE PARTS LIST . .........................................10
6 COMPLETE CLOSING ASSEMBLY . ..................10
6.1 Minimum level of protection
provided by the safety edge . ...............10
6.2 Risk of crushing in the opening area ..10
6.3 Impact in the opening/closing area ....10
Example of typical installation ............27
ANNEXES
- Instructions for the final user
- Terms of warranty
OVERVIEW
SCOPE OF THE INSTRUCTIONS
These instructions were prepared by the manufacturer and
are an integral part of the product. The operations described
are intended for adequately trained and qualified operators and
must be carefully read and preserved for future reference.
Chapters "2 RESIDUAL RISK WARNINGS" and "4 OPERA-
TING INSTRUCTIONS" contain all the information that DEA
System provides in order for the product to constantly satisfy
the Essential Safety Requirements prescribed by the Machinery
Directive (European Directive 2006/42/CE).
Read these chapters carefully because they contain impor-
tant instructions for safe installation, use and maintenance and
important warnings regarding the residual risks remaining even
after all the safety devices and measures described have been
applied.
The product is designed for installation in complete closing
systems subject to specific legislation. Chapter 6 "COMPLETE
CLOSING ASSEMBLY" provides useful information for the respect
of the Essential Safety Requirements for special types of closing.
Operating instructions and warnings

1 PRODUCT CONFORMITY

DEA System guarantees the conformity of the product to
European Directives 2006/42/CE regarding machinery safety,
2004/108/CE electromagnetic compatibility and 2006/95/CE
low voltage electrical equipment. DEA System also encloses the
manufacturer's Declaration of Conformity with these instructions
(see Directive 2006/42/CE Art. 4, paragraph 2).
2 RESIDUAL RISK WARNINGS
Read these warnings carefully; the failure to respect
the following warnings can create risk situations.
WARNING Using this product under unusual conditions not
foreseen by the manufacturer can create situations of danger,
and for this reason all the conditions prescribed in these in-
structions must be respected.
WARNING Under no circumstances must the product be
used in explosive atmospheres or surroundings that may pro-
ve corrosive and damage parts of the product.
WARNING All installation, maintenance, cleaning or repair
operations on any part of the system must be performed
exclusively by qualified personnel with the power supply
disconnected working in strict compliance with the electrical
standards and regulations in force in the nation of installa-
tion.
WARNING Starting the operator with the lever unit set on the
released position may severely injure your arms and legs. Be
extremely careful! Release the lever unit only if really neces-
sary: If there is a power supply failure disconnect manually the
power supply of the operator by using the apposite switch; in
this way, when the power is back you will be able to start the
operator only after blocking the lever unit again.
WARNING All other adjustment/setting operations beyond
the adjustment of the oil flow are made by the manufacturer.
Tampering with these settings may cause malfunction and/or
situations of risk to people, animals and property. Refrain from
performing any operations not authorised by DEA System.
WARNING Before doing any maintenance operation take off
the foundation box lid (by unscrewing the two fixing screws;
see F5 page 31); this lid offers protection against the risk of
scissor movement due to the presence of moving levers. Once
the maintenance operation is completed place back immedia-
tely this protection.
WARNING Using spare parts not indicated by DEA System
and/or incorrect re-assembly can create risk to people, ani-
mals and property and also damage the product. For this
reason, always use only the parts indicated by DEA System
and scrupulously follow all assembly instructions.
WARNING Awareness of the operation of the key-release
mechanism (see F8 Page 32) is essential for all users of the
automatism because the failure to use the device quickly
during emergencies can jeopardise people, animals and pro-
perty. Enclosure I to these instructions, which the installer is
required to deliver to the final user, illustrates operation and
can be detached.
GH OS T 200
ENGLISH
A1
A2
A3
A4
A5
7
A6
A7
A8
Tabla de contenido
loading