What To Do In Case Of A Problem; Electrical Connection - Kuppersbusch EKWI 3740.0 W Instrucciones De Instalación

Ocultar thumbs Ver también para EKWI 3740.0 W:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
VI) Second step: new setup
Take a pot with a ferromagnetic bottom with a minimum diameter of 16 cm2) Select
a cooking zone by pushing on the corresponding [ C ] display
3) Place the pot on the area to be set
4) Wait until the [ C ] display becomes a [ - ]. The selected cooking zone is now
configured.
5) Follow the same procedure for each cooking zone with a [ C ] display.
6) All the cooking zones are configured once all the displays are turned off.
Note: .....Please use the same pot for the whole procedure.
Never put several pots together on the zones during the setup-process.

WHAT TO DO IN CASE OF A PROBLEM

The symbol [ E4] appears :
 Reconfigure the table
 If the symbol remains, please contact the After sales service

ELECTRICAL CONNECTION

 The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly aware, and in respect of the normative
regulations
 Protection against parts under tension must be ensured after the building.
 The data of connection necessary are on the stickers place on the hob casing near the
connection box.
 The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
 The electrical circuit must be separated from the network by adapted devices, for
example: circuit breakers, fuses or contactors.
 If the appliance is not fitted with an accessible plug, disconnecting means must be
incorporated in the fixed installation, in accordance with the installation regulations.
 The inlet hose must be positioned so that it does not touch any of the hot parts of the hob
or oven.
CONNECTION OF THE HOB
For the various kinds of connection, use the brass bridges which are in the box next the
terminal.
Caution!
- Connect always the earth wire.
- Respect the connection diagram.
- This device is intended for a supply of 230 V ~ 50/60 Hz
- The connection box is located underneath at the back of the hob casing. To open the cover
use a medium screwdriver. Place it in the slits and open the cover.