Changing the Battery Type Setting
The standard setting for the onboard battery charger is
Flooded/AGM. EXCEPTION: If your machine was
ordered from NSS equipped with Gel batteries, then the
charger was configured for Gel batteries at the factory.
Configuring the Charger for Gel batteries:
Remove the top cover.
1.Pull the jumper off the board (position 1), and then
store the jumper for later use at position 2. See
photo below.
2.Reinstall the top cover.
1. The green wire outputs a battery voltage when the
charger is not plugged in to AC to provide an
Top cover
screws
Interlock function.
2. Securely fasten the black ring terminal from the charger
to the negative terminal ("-", "NEG", NEGATIVE") of the
battery pack.
3. Select Charge Algorithm if battery type is other than
factory default.
Position 2
Storage Location
For jumper
Position 1
Remove
jumper for gel
Configure the Charger for Flooded/AGM batteries
1.Remove the top cover
2.Pull the jumper from the storage location (position 2),
and install the jumper at position 1.
3.Reinstall the top cover.