Button combinations

Main switch ON
ON
Heating and Blower buttons pressed
at the same time and the main switch ON
1. Work mode
1.1 Setpoint display (after switching on the device)

Main switch (3) ON

• After switching on the device, the values last set appear on the display (5) (Fig. 3).
• Heating, plower and drive are switched off in this menu.
• The user can use the controls (4) here to perform all settings which are described in
the following chapters.
• If, however, the heating element temperature is higher than 80°C when switching
on, the display will immediately change to the Cool down mode (section 1.8, Cooling
down) in which the blower is always operated at full power, thus cooling down the
welding nozzle (9). It is possible to change back to Work mode from this mode at
any time.
• If the heating element temperature reaches 60°C during cooling down, the blower will
continue to operate for 2 minutes and then switches off automatically. The display (5)
changes back to the Setpoint display (Fig. 3).
• Turning the e-Drive
(Fig. 4; section 1.7, Selecting profiles).
ON
ON
to Profile allows various welding profiles to be selected
Work mode
Chapter 1
Profile setup
Chapter 2
(Fig. 3)
(Fig. 4)
25