Creating Multiple Or Group Controls; Tips And Recommendations; Problems With The Heating Modulis Rts Ramp - SOMFY Heating Modulis Ramp RTS Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Installation guide
2)
Briefly press the PROG button on the RTS control point (b) to be
added or removed:
- The heating lamp comes on then goes out; the RTS control point
has been added/removed.

7.3 Creating multiple or group controls

7.3.1 Group control
Group control: an RTS control point controls several Heating Modulis RTS Ramps.
1) Switch off the power supply to the Heating Modulis RTS Ramp (c, d
and e) to be controlled by a single RTS control point.
2)
Switch on the power supply to the first Heating Modulis RTS Ramp
(e) to be linked to the RTS control point.
3)
Simultaneously press the Up/Down buttons on the RTS control
point: the heating lamp comes on then goes out.
4)
Press the PROG button on the RTS control point: the heating lamp
will come on then go out again to indicate that the RTS control point
has been programmed into the Heating Modulis RTS Ramp.
5)
Switch off the power supply to the newly linked Heating Modulis RTS
Ramp (c) before adding the next Heating Modulis RTS Ramp.
6)
Switch on the power supply to another Heating Modulis RTS Ramp
to be linked and repeat steps 3), 4) and 5) for each Heating Modulis
RTS Ramp (d, e, etc.).
7)
Switch on the power supply to all the Heating Modulis RTS Ramps
linked to the RTS control point.
7.3.2 Multiple control
Multiple control: a Heating Modulis RTS Ramp is controlled by several RTS control points.
Caution! A maximum of 12 control points may be programmed into a Heating Modulis RTS Ramp.
1) Press the PROG button on the programmed RTS control point (a)
until the heating lamp comes on then goes out: the Heating Modulis
RTS Ramp will be in its programming mode for 2 minutes.
2)
Briefly press the PROG button on the RTS control point (b) to be
added:
-
The heating lamp comes on then goes out; the RTS control point
has been added/removed.
-
Repeat these two steps to add each RTS control point.

8. Tips and recommendations

8.1 Problems with the Heating Modulis RTS Ramp?

Problems
The Heating Modulis RTS
Ramp cannot be opera-
ted by pressing one of the
buttons on the RTS control
point.
The Heating Modulis RTS
Ramp does not heat up
sufficiently.
Copyright © 2008 Somfy SAS. All rights reserved.
5061611X02_HMR_Ramp_RTS.indb 23
Possible causes
The power supply is faulty.
The RTS control point has not been
programmed into the Heating Modulis RTS
Ramp .
The RTS control point used is not compati-
ble with the Heating Modulis RTS Ramp .
The batteries in the RTS control point are
weak.
The correct distance and height of the
installation have not been respected.
Heating Modulis RTS Ramp
+
1
a
PROG.
1
OFF
2
c
ON
4
c
PROG.
1
a
PROG.
Solutions
Check the power supply.
Follow the procedure for programming an RTS
control point.
Ensure the two products are compatible.
Replace the batteries with identical ones.
Check the distance and height of the installation.
2
b
PROG.
2 min.
c
d
e
3
c
c
+
2
b
PROG.
2 min.
23
25/05/09 18:41:04
Tabla de contenido
loading

Este manual también es adecuado para:

5061611a

Tabla de contenido