Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 172

4) Testing

Check the system is correctly connected and fully operational as
follows:
• Power the DECODER and make sure the LED flashes 5 times
(memory empty).
• Press the small button on the DECODER; the LED flashes for 30
seconds and the READER or KEYPADS emit tones. Wait until the
30 seconds are up or press the small button once more.
• Check the READER by holding a card up to it for a few moments
(do not keep it there for more than two seconds otherwise you
Table "A"
List of tones
1 tone
Key pressed on the KEYPAD or CARD read correctly
2 rapid tones
Invalid combination, CARD not active
3 tones
Programming phase correctly terminated
5 rapid tones
Minor error, the operation has not been completed
10 rapid tones
Serious error, programming phase aborted
12
might programme it) whenever tones are expected to be heard.
• Check the KEYPADS by pressing all the keys one after the other; a
brief tone should be emitted every time you press a key; just the
confirmation keys
and
tone.
To check the relays on the outputs, a combination or a CARD must
already have been entered during the programming phases.
During programming and use, the KEYPADS or the READER emit
tones signalling regular operation or any errors.
will produce an incorrect combination
Example
... ...
Tabla de contenido
loading

Este manual también es adecuado para:

Moon motMoon momMoon mocard

Tabla de contenido