2.3.4 Flow test and adjustement (available as an option)
Before installing the cleaner head, test and adjust to determine the ideal flow.
To do this, remove the cleaner from the hose while keeping the cleaner immersed, and replace with the flow switch
(see image
). Start the pump.
Check that the red indicator on the tester (side view) is on setting n°3 (see image
If necessary, use the valves located in the pool technical room to adjust the flow so that the indicator is on setting 3.
• For installation in a pool with a single skimmer, the flow is regulated by the flow regulation valve. The red indicator
must be in position 3.
• For installation in a pool with several skimmers, leave the valve for the skimmer connected to the hose open, then
gradually close the other skimmer until the indicator is on setting 3.
• For installation on a brush socket, leave the suction line open and gradually close the skimmer line until the flow
reaches setting 3.
If the flow is in the low zone (0-2):
• Check and clean the pool filter and baskets if necessary.
• Check that the valves that control the suction lines are correctly open.
• Increase the flow regulation on the regulation valve.
If the flow is in the high zone (4-6):
• If you are using the brush socket, gradually close the valve until position 3 is reached.
• Reduce the flow regulation on the regulation valve.
• Slightly open the bottom drain to reduce the flow a little more.
Stop the pump. While keeping the hose immersed, remove the flow tester.
).
EN
9