Cleaning And Care; Product Registration; Replacement Parts - Blue Rhino GBC1932L Manual Del Proprietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

10
Operating Instructions (continued)
Important: Always use the lighting rod (included) when lighting burners with a match .
9 .
After lighting, observe the burner flame . Make sure all burner ports are lit and flame height
matches illustration (Figure 5) .
Note: Each burner lights independently - repeat steps 5-9 for the other burners .
W CAUTION: If burner flame goes out during operation, immediately turn
the control knobs to the " OFF" position,
LP gas tank valve "CLOSED" and open lid to let the gas clear for 5
minutes before re-lighting.
Turning Off
1 .
Turn LP gas tank valve to "CLOSED ."
2 .
Turn all control knobs clockwise to the " OFF" position .
Note: A "poof" sound is normal as the last of the LP gas is burned .
3 .
Disconnect LP gas tank per "Disconnecting LP Gas Tank" section .
Controlling Flare-ups
W CAUTION: Putting out grease fires by only closing the lid is not
possible.
1. If a grease fire develops, turn control knobs to the " OFF" position
and LP gas tank valve "CLOSED." Do NOT use water on a grease
fire. This can cause the grease to splatter and could result in
serious burns, bodily harm or other damage.
2. Do NOT leave grill unattended while preheating or burning off food
residue on (HIGH). If grill has not been cleaned, a grease fire can
occur.
W WARNING: When cooking, fire extinguishing materials should be
readily accessible. In the event of an oil/grease fire, use type BC dry
chemical fire extinguisher or smother with dirt, sand or baking soda.
Do NOT attempt to extinguish with water.
Flare-ups are a part of cooking meats on a grill and add to the unique flavor of grilling .
Excessive flare-ups can over-cook your food and be dangerous.
Important: Excessive flare-ups result from the build-up of grease in the bottom of your grill .
If a grease fire occurs, close the lid AND turn the control knob(s) to " OFF" until the grease
burns out . Be careful when opening the lid as sudden flare-ups may occur .
If excessive flare-ups occur, do NOT pour water onto the flames .
Minimize Flare-ups:
1 .
Trim excess fat from meats prior to cooking .
2 .
Cook high fat content meats on (LOW) setting or indirectly .
3 .
Ensure that your grill is on a hard, level, non-combustible surface and the grease is
allowed to drain into grease receptacle .

Cleaning and Care

W CAUTION:
1. All cleaning and maintenance should be done when grill is cool
and with the fuel supply disconnected.
2. Do NOT clean any grill part in a self-cleaning oven. The extreme
heat will damage the finish.
3. Do NOT enlarge valve orifices or burner ports when cleaning the
valves or burners.
Notices
1.
This grill should be thoroughly cleaned and inspected on a regular basis.
2.
Abrasive cleaners will damage this product.
3.
Never use oven cleaner to clean any part of grill.
Before Each Use:
1 .
Keep the grill area clean and free from any combustible materials, gasoline, and other
flammable vapors and liquids .
2 .
Do NOT obstruct the flow of the combustion of LP gas and the ventilation of air .
3 .
Keep the ventilation opening(s) of the LP gas tank area free and clear from debris .
4 .
Visually check the burner flames to make sure your grill is working properly (Figure 6) .
5 .
See sections below for proper cleaning instructions .
6 .
Check for obstructions of airflow to the burners . Spiders, insects and webs can clog the
burner/venturi tube . A clogged burner tube can lead to a fire .
Cleaning Surfaces
1 .
Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water .
2 .
For stubborn surfaces, use a citrus-based degreaser and a nylon scrubbing brush .
3 .
Rinse clean with water .
4 .
Allow to air dry .
Outdoor LP Gas Griddle
Model No. GBC1932L
Cleaning and Care (continued)
Cleaning Main Burners
1 .
Turn LP gas tank valve to "CLOSED ."
2 .
Turn all control knobs clockwise to the " OFF"
position .
Note: A "poof" sound is normal as the last of the
gas is burned .
3 .
Disconnect LP gas tank per "Disconnecting LP
Gas Tank" section .
4 .
Remove cooking grids and heat plates .
5 .
Remove burners by removing the fasteners, which
secure the burners to the grill bottom .
6 .
Lift burners up and away from gas valve orifice .
7 .
Disconnect wire from spark electrode .
8 .
Clean venturi of each burner with small bottle
brush or compressed air .
9 .
Remove all food residue and dirt from burner
surface .
10 . Clean any clogged ports with a stiff wire (such as
an opened paper clip) .
11 . Inspect burners for any damage (cracks or holes) .
If damage is found, replace with new burner(s)
from manufacturer .
12 . Re-install burner(s) . Checking to insure that gas
valve orifice is correctly positioned inside each
burner/venturi tube . Also, check position of spark
electrode .
13 . Replace heat plate(s) and cooking grid(s) .
14 . Connect LP gas tank per "Installing LP Gas Tank"
section .
15 . Perform leak test per "Checking for Leaks"
section .
Before Storing
1 .
Turn LP gas tank valve to "CLOSED ."
2 .
Turn all control knobs clockwise to the " OFF" position .
Note: A "poof" sound is normal as the last of the gas is burned .
3 .
Disconnect LP gas tank per "Disconnecting LP Gas Tank" section .
4 .
Clean all surfaces .
5 .
Lightly coat the burner(s) and cooking grid(s) with cooking oil to prevent excess rusting .
6 .
If storing the grill indoors, disconnect the LP tank per "Disconnecting LP Gas Tank" section .
7 .
Place the protective cap cover on the LP tank and store the tank outdoors in a well-
ventilated area out of direct sunlight .
8 .
If storing the grill indoors, cover the grill and store in a cool dry place .
9 .
If storing the grill outdoors, cover the grill with a grill cover for protection from the weather .

Product Registration

For faster warranty service, please register your product immediately . To register, call
1 .800 .694 .0013 .

Replacement Parts

For replacement parts, call 1 .800 .694 .0013 .
Figure 6
Burner Flame Conditions
Use this chart to see if your burners
need to be cleaned .
1-2 in. /
25.4 - 50.8 mm
Normal: Soft blue flames with yellow
tips between 1 in . - 2 in . height .
Needs cleaning: Noisy with hard
blue flames .
Has to be replaced: Wavy with
yellow flames .
Tabla de contenido
loading

Tabla de contenido