Installation
Wall mounting
A
E
-Remove the connection panel (D).
-Remove the front (B) from the housing (A).
Panel mounting only
-Replace the gasket installed in the front panel with
the included panel mounting gasket (K).
-Make a hole of the specified size in the panel
-Select the most appropriate cable input configuration for the
installation
(fig. 1).
-Drill the holes for the cable glands using the pre-stamped holes as
a guide.
Wall mounting only
-Drill 3 holes in the wall to match the fixing holes on the
housing (E).
-Insert and tighten the 3 bolts and wall plugs (F).
Panel mounting only
-Finish drilling the top holes (L) with a 4 mm bit.
-Insert the cables through the cable glands. If you choose the upper inlets, guide the cables as shown on figure
-Connect the battery cable to the panel connector (Page 14).
Wall mounting only
-Fit the front of the housing (B).
-Insert and tighten the two screws on the front (G).
Panel mounting only
-Attach the front to the housing, through the panel, and affix it with the
screws provided (G and J).
-Connect cables following the drawings in page 16.
-Close the connection panel (D), insert and tighten the fixing screws (H).