Starting the Heater (Ignition):
1. Fill the tank with Kerosene or other approved
fuel until needle on fuel gauge points to "F".
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong
(grounded) power source. You must use a three
prong (grounded) extension cord that is at
least 1.8 meters long and is a minimum of 14
AWG rating.
NOTE: On first ignition or after refueling, you may
hear a grinding sound just before ignition. This is
the fuel pump removing the air from the fuel line.
Your heater will start up within seconds. If it does
not start repeat
start-up procedures with fuel gauge reading at least
1/2 tank.
NOTE: Smoking may occur on first ignition.
NOTE: The electrical components of these heaters
are protected by a fuse mounted in the PC board.
If the heater fails to ignite, check this fuse first
and replace if necessary. Also check the power
source to be sure the proper voltage is being
provided to the heater.
1. Complete steps 1-3 above.
2. Push the power switch to the "ON" position.
The power indicator lamp will light and heater
will ignite (see Figure 10).
Figure 10
© 2018 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
®
OPERATION (CONT.)
Power Switch
Stopping the Heater (Cool Down):
1. Turn the power switch to the "OFF" position.
Combustion will stop and the Cooling Cycle
will begin.
- 80-OFR: approx. 5 mins
- 125-OFR-A: approx 3 mins
When the Cooling Cycle is complete the fan
will stop running and it will be safe to unplug
the heater.
NOTE: Unplugging the heater before the Cooling
Cycle has been completed may cause overheating,
possible damage to the heater and heat plate.
WARNING
cycle has been completed.
Restarting the Heater:
1. Wait ten seconds after Cooling Cycle has been
completed.
2. Follow all start-up procedures above.
Electrical Outlet (80-OFR Only):
-
Never plug an appliance with more than a 5
amp rating into this outlet (see Figure 11).
-
Always keep outlet covered when not in use
Figure 11
8
Kerosene Radiant Heater User's Manual
DO NOT disconnect
heater from power
source before cooling
Electrical Outlet
80-OFR Only