Starting the Generator (Recoil Start-Gasoline)
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.
2. Check oil level and fuel.
3. Make sure the LPG cylinder knob is fully closed.
4. Turn the fuel selector switch to "GAS" position(4:30 o'clock).
5. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned
on.
6. Flip the engine switch to the "RUN"(l) position.
English
7. Push the battery power restore switch for about
3 seconds and then release.
8. Pull the choke lever out to the "CHOKE" position.
9. Pull the starter cord slowly until resistance is
felt and then pull rapidly.
10. Push the choke button to the "RUN" position.
11. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
NOTE:
The gasoline valve is OPEN, w
selector switch is in "GAS" position(4:30 o'clock).
To close this valve, turn the slector switch to the
" LPG" position (1:30 o'clock).
Starting the Generator (Recoil Start-LPG)
NOTE: The generator will NOT start with LPG without
battery power or an appropriate connection.
1. Before starting the generator, check for loose
or missing parts and for any damage which
may have occurred during shipment.