SYNQ DLP-6 MK2 Manual De Instrucciones página 9

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
ENGLISH
o BANDWIDTH: turn the DIAL (4) to change from 0,016 (narrow) to 4,000 (wide).
 LS1: Low-shelf 6dB, with the following parameters:
o GAIN: turn the DIAL (4) to adjust the gain from -30dB to +15dB in 0,1dB steps.
o FREQ: turn the DIAL (4) to adjust the frequency from 19,7Hz to 2kHz.
 LS2: Low-shelf 12dB, with the following parameters:
o GAIN: turn the DIAL (4) to adjust the gain from -30dB to +15dB in 0,1dB steps.
o FREQ: turn the DIAL (4) to adjust the frequency from 19,7Hz to 2kHz.
 HS1: High-shelf 6dB, with the following parameters:
o GAIN: turn the DIAL (4) to adjust the gain from -30dB to +15dB in 0,1dB steps.
o FREQ: turn the DIAL (4) to adjust the frequency from 3886Hz to 21,9kHz.
 HS2: High-shelf 12dB, with the following parameters:
o GAIN: turn the DIAL (4) to adjust the gain from -30dB to +15dB in 0,1dB steps.
o FREQ: turn the DIAL (4) to adjust the frequency from 3886Hz to 21,9kHz.
OUTPUT PARAMETERS – HIGH-PASS FILTER (CROSSOVER)
All outputs are equipped with a fully adjustable high-pass filter. Use the /buttons (9&10) to jump
between the different parameter settings:
 CUTOFF FREQUENCY: turn the DIAL (4) to adjust the frequency from 19,7Hz to 21,9kHz or to turn it OFF.
 FILTER TYPE: turn the DIAL (4) to select one of the filter types (Butterworth, Bessel or Linkwitz-Riley) and
corresponding slopes (12dB/oct, 18dB/oct, 24dB/oct or 48dB/oct)
OUTPUT PARAMETERS – LOW-PASS FILTER (CROSSOVER)
All outputs are equipped with a fully adjustable low-pass filter. Use the /buttons (9&10) to jump between
the different parameter settings:
 CUTOFF FREQUENCY: turn the DIAL (4) to adjust the frequency from 19,7Hz to 21,9kHz or to turn it OFF.
 FILTER TYPE: turn the DIAL (4) to select one of the filter types (Butterworth, Bessel or Linkwitz-Riley) and
corresponding slopes (12dB/oct, 18dB/oct, 24dB/oct or 48dB/oct)
OUTPUT PARAMETERS – LIMITER
All outputs are equipped with a fully adjustable limiter. Use the /buttons (9&10) to jump between the
different parameter settings:
 ON/OFF: turn the DIAL (4) to set the limiter ON or OFF.
 THRESHOLD: turn the DIAL (4) to set the threshold value between -20dBu and +10dBu in 1dBu-steps.
 RATIO: turn the DIAL (4) to set the limiter compression ratio:
 Lower ratios: 1,2/1 ~ 1,5/1 ~ 2/1 ~ 3/1 ~ 4/1 ~ 6/1
 Higher ratios: 10/1 ~ 20/1 ~ Infinite (brick-wall limiter)
If you want to use the limiter for protection then you should choose a higher compression ratio (20/1 or inf.)
 ATTACK: turn the DIAL (4) to set the attack time: 0,5ms ~ 1ms ~ 2ms ~ 5ms ~ 10ms ~ 20ms ~ 50ms.
 RELEASE: turn the DIAL (4) to set the release time: 10ms ~ 20ms ~ 50ms ~ 100ms ~ 200ms ~ 500ms ~
1s.
OUTPUT PARAMETERS – LINK SETTINGS
You can link the settings of the selected output channel with one or more of the other
5 outputs. You only have to setup the current output  all settings of the linked
outputs will be identical at all times. The example below will show you how to link one
or more outputs:
Example: we will link output1 "OP1" to outputs "OP3" and "OP5" (and NOT to outputs
"OP2", "OP4" and "OP6"):
 Picture A: Turn the DIAL (4) to set the link OFF, press
output.
 Picture B: Turn the DIAL (4) to set the link ON, press
 Picture C: Turn the DIAL (4) to set the link OFF, press
output.
 Picture D: Turn the DIAL (4) to set the link ON, press
 Picture E: Turn the DIAL (4) to set the link OFF
 Picture F: Press the SAVE-button (11) to confirm
on outputs 1, 3 and 5 will have the same settings!
SYNQ
®
button(10) for next
button(10) for next output.
button(10) for next
button(10) for next output.
the links are made, from now
7/96
OPERATION MANUAL
DLP-6 MK2
Tabla de contenido
loading

Tabla de contenido