Master Audio
Do not connect Xcellence series units in parallel using PowerCon- PowerCon without
earth.
Fig.14. Parallel connection for the XcellenceE series(signal)
Fig.15. Parallel connection for the XcellenceE series (mains)
7.2. Parallel connection with subwoofer
You can connect the X18WE subwoofer in parallel with X12CE, X15CE or X15LTE
cabinets. Please, follow the same parameters as explained in figures 14 and 15.
Never connect more than 4 units using the AC Stacking socket.

8. OVERVOLTAGE PROTECTION

The Xcellence series models incorporate an exclusive protection by Master Audio
against mains voltage overload and other related problems (lose of neutral,
connection between phases, etc)
In the mains input an electronic circuit compares the input voltage with a reference
value. When the input exceeds 250 Volts, the circuit reacts by blocking the input
tension until it returns to its correct limits (230V +/- 10%).