Welbilt Frymaster Dean Super Runner Serie Manual De Instalación, Operación Y Mantenimiento página 8

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Manifold Support Bracket
Gas Burner
See Detail A
Orifice
Temperature
Control
1.6 Gas Conversion Components
Use the following components to convert from natural gas to propane and vice-
versa. See Section 1.5 for orifice quantities required for conversion.
Natural Gas to Propane Kits
SR42 - 8261817
SR52 - 8262018
SR62 - 8262020
Bushing, NPT Flush, SR 42 series only
Pilot Orifice (16LP)
Burner Orifice, 1.51mm (#53)- SR52 & SR62 Series Only Burner Orifice, 2.53mm (#39)- SR52 & SR62 Series Only
Burner Orifice, 1.70mm (#51)- SR42 Series Only
* Burner orifices listed above are for fryers operating at altitudes of 2000 feet (610 meters) or less. For altitudes
greater than 2000 feet (610 meters), contact the factory for the correct orifice size.
SUPER RUNNER SERIES GAS FRYERS
CHAPTER 1: INSTALLATION INSTRUCTIONS
Frypot Assembly
Pressure
Test
Spigot
Gas
Manifold
Assembly
Typical gas valve, burner and orifice locations (SR42 shown above).
1/2—3/4 Reducer
Bushing
Gas Valve
1.63-inch [41-mm]
Gas Manifold
Burner/Orifice Location
Proper Regulator Must Be Installed
Propane to Natural Gas Kits
SR42 - 8262017
SR52 - 8262019
SR62 - 8262021
Bushing, NPT Flush, SR 42 series only
Pilot Orifice (26N)
Burner Orifice, 2.80mm (#35)- S42 Series Only
1-5
Burner
1.30-inch [33-mm]
Orifice
Detail A
Propane Applications:
Propane Applications:
Proper Regulator Must Be
Installed
Regulator
Tabla de contenido
loading

Tabla de contenido