INSERTING THE FUEL CELL IN TO THE TOOL
● Be sure to release your finger from the Trigger.
WARNING:
● Do not press the Contact Arm against the object.
Actuator
2
1
Green
Metering Valve
Fuel Cell
Green Adapter
q Push up and pull the Actuator to this side to open it.
CAUTION:
● Confirm that the Metering Valve of the Fuel Cell is green.
w Directing the Valve Stem of the Metering Valve forward (toward the Air Filter Cover),
set the Fuel Cell.
e When you open the Actuator, you can see a Green Adapter.
Fit the Valve Stem into this adapter.
r Put the Actuator over the Metering Valve and push it down to latch.
18