To remove filter:
1.
When filter life reaches programmed time (1000
hours), red Reset indicator light will flash twice
per second.
2.
Turn off unit.
CAUTION: The internal metal ring
carries an electrical charge during
operation.
Turn
attempting to remove cover.
3.
Rotate cover counterclockwise and remove it,
along with the prefilter. See Figure 8-4.
4.
Hold the frame stationary, and rotate filter
counterclockwise to remove.
5.
Clean dust from filter with vacuum or soft bristle
brush. Blow dust from recessed areas of filter
with a household air blower. Also clean out any
residual dust from inside the unit.
To install cleaned or replacement filter:
6.
Center filter onto stator and turn it clockwise
(about 1/8 of a turn) until it fully engages – you
will feel a hard stop.
7.
Install cover and rotate clockwise until it fully
engages. A lock/unlock graphic is molded into
left and right edges of the cover as a guide.
Note: A sensor prevents unit from starting if
cover is not installed properly.
8.
Plug in unit. Red Reset indicator light will flash.
9.
Press and hold Power button for 5 seconds until
red indicator light goes off. Filter life count is
now reset.
off
unit
before
9
9.2 Anion generator maintenance
Remove dust regularly from the anion generator (i.e.
carbon brush) with the provided cleaning brush. See
Figure 9-1.
Figure 9-1
9.3 Additional servicing
Any additional servicing should be performed by
authorized service personnel.