Troubleshooting - Rheem GEN12S Manual Del Operador

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Troubleshooting

Problem
Engine is running, but no AC output is
available.
Engine runs good at no-load but "bogs
down" when loads are connected.
Engine will not start; or starts and runs
rough.
Engine shuts down during operation.
Loss of power on essential circuits.
Cause
1. Circuit breaker open or defective.
2. Fault in generator.
3. Poor wiring connections or
defective transfer switch.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Shorted generator circuit.
4. Fuel Pressure is incorrect.
5. Natural gas fuel mixture is
incorrect.
1. 15 Amp fuse missing or blown.
2. Out of fuel.
3. Failed battery.
1. Out of fuel.
2. Fault indicator blinking.
1. Generator circuit breaker is open.
2. Transfer switch problems.
Correction
1. Reset or replace circuit breaker.
2. Contact local service facility.
3. Check and repair.
1. Disconnect shorted electrical load.
2. See Essential Circuits.
3. Contact local service facility.
4. See The Gaseous Fuel System in
the Installation Manual.
5. See The Gaseous Fuel System in
the Installation Manual.
1. Install (new) 15 Amp fuse. See
Controls.
2. Open fuel valve(s); check propane
tank.
3. Replace battery.
1. Check fuel valves, fill propane tank.
2. Count blinks and refer to Fault
Detection System.
1. Reset circuit breaker.
2. See the transfer switch manual.
17
Tabla de contenido
loading

Este manual también es adecuado para:

Gen15sGen20bGen25b

Tabla de contenido