1) HANDLING AND TRANSPORT
The equipment is packed in a wooden crate (fig. A) which is suitable for
lifting by fork lifts or transpallette in order to avoid possible damages. The
equipment must be moved by qualified personnel.
The packing containing the equipment has to be handled carefully, using a
fork lift, avoiding impacts or falls due to a bad slinging, that could damage
the integrity of the product. It is recommended to use proper individual
protection devices (approved gloves of class II).
2) UNPACKING
The wooden packing can be recycled, therefore it has to be disposed in the
special waste plan for recycling. Keep the packing away from children. It is
advisable to use a wooden board for any handling of the cabinet in order to
avoid damages of the structure (fig. A).
Carefully unpack the cabinet, paying attention so as not to damage it or
throw parts necessary for the assembling away, considering that in some
models there are glasses and also inside the packing you will find all the
necessary assembling parts (for example screws). During the handling of the
cabinet to install it on its place, the cabinet must be never pulled on its side
ends (fig. B).
3) STORAGE
In case of prolonged stop of the equipment, after having used it, make a full
cleaning of the equipment and keep it away from all weathers.
4) COMPLAINTS
On receipt of the refrigerated equipment verify immediately if there are
transport damages. In case the unit is damaged in any way, notify immediately
the driver and, within 3 days, the shipping company by registered letter.
Every complaint must arrive at the manufacturer within 8 days from receipt
of the equipment. After this term the manufacturer will not take any
responsibility.
5) IMPORTANT INSTRUCTIONS AND SUGGESTIONS
Before using the equipment it is important to read these instructions
carefully and keep them, as well as the CE Certificate of conformity (that is
included inside the envelope), for future reference. An improper use of the
equipment can be dangerous. Before connecting the refrigerated unit, make
sure that the power supply voltage is as indicated on the label (fig. C). To
guarantee the electrical safety of this equipment, it must be connected to
a grounded power socket in compliance with the current legislation of the
destination country.
For usage of the unit, as every electrical device, basic rules have to be
followed:
- Do not touch or plug the equipment with damp or wet hands or feet;
- Do not use the equipment with barefoot;
- Do not pull the electrical cable to unplug it;
- Do not expose it to the atmospheric agents (sun, snow, rain, etc.);
- Do not wash the equipment with water jets;
- Do not allow children to use it without adult supervision and make sure
that they do not play with the equipment;
- Before starting any cleaning or maintenance operation, it is
necessary to unplug the equipment;
- In case of breakdown or bad functioning, disconnect the unit and do not
attempt to make any modification;
- It is forbidden to put boxes or other objects over the roof of the wall-
cabinet (fig. D).
- This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety;
- Do not cover the equipment with clothes or other things during its
working.
6) WORKING TEMPERATURE
This equipment is manufactured in conformity with the ambient conditions
of climatic class 3 (25°C – 60% R.H.) according to the standard UNI EN
ISO 23953:2006, and the refrigeration power has been calculated referring
to the climatic class 3. The refrigerated unit maintains its performance
characteristics with an ambient temperature and relative humidity of no
GB
more than: + 25° C and 60% R.H. (relative humidity). In case the ambient
conditions are not included in the above mentioned ones, a lower
performance must be expected.
The ambient where the equipment is installed has to be proper and in
conformity with the hygienic and sanitary rules in force.
7) INSTALLATION
The equipment must be installed in a suitable, dry, non-aired place far away
from doors and on a level floor in order to prevent noise and vibrations
during the working of the unit and also to avoid higher energy consumption
and a shorter compressor life (fig. E). Do not try to correct possible
imperfections of the floor level with pieces of wood, carton or similar, but
use only the feet screwing or unscrewing them (without taking them off)
until you reach a perfect levelling.
The refrigerated equipment should never be installed near sources of heat
such as radiators, fan-heaters, direct or indirect sunlight or other equipment
which produce heat and in line with draughts coming from doors, windows
or air-conditioning systems (fig. F).
Do not close or obstruct the ventilation openings of the refrigerating unit,
because this would stop the airflow which cools the refrigeration unit
causing bad working (fig. G).
The equiment has to be installed at a distance of minimum 10 cm. from the
wall.
Also the equiment must never be fitted in furniture covering the ventilation
grid and without living a space of 10 cm. between the equipment and the
wall.
8) ASSEMBLING
The equipment has to be finished with the assembling of the glasses (except
for the models Small and Plick) and of the shelves, that have to be fitted by
qualified people after the unit has been installed in its working place.
The assembling instructions are included in the envelope containing the
equipment documents and that is supplied with the packed equipment.
The equipment has to be installed in its definitive place and levelled by
qualified people.
9) ELECTRICAL POWER / CONNECTION
First of all make sure that there is an efficient ground system in compliance
with the current legislation of your country regarding electrical safety. When
in doubt, request a careful check from a qualified technician.
The unit is equipped with the plug and electrical cable mod. Schuco (fig. H).
The cable has to be connected at 3 mt. max. to a 0,03A differential fused
isolator. Never connect the cable to main supply line directly.
The necessary operations to connect the unit are:
1) Verify that the power supply voltage is as indicated on the machine
rate plate (fig. C) 230V/50 Hz monophase, or 220V/60Hz or 110V/60Hz.
We recommend to connect the unit to a dedicated circuit and not to use
damaged sockets, extension sockets or multiple sockets.
2) In case of incompatibility between the socket and the plug
of the unit, the plug should be replaced with a suitable one by
a qualified technician. It is forbidden to use adapter sockets or
extension sockets.
3 ) Do not connect any other appliance to the same power socket.
4) Do not pull the electrical cable or the unit to unplug the equipment from
the socket (fig. I).
5) Pay attention that the power supply cable is laid in such a way as to
prevent it from being damaged or becoming hazardous to people and things.
6) In case the power supply cable is damaged, it should be replaced only by a
qualified technician (electrician) with an equivalent cable.
7) We recommend not to use extension sockets, worn down cables, cables
with damaged or fissured insulation as they are very dangerous: they could
cause sparks, electric shock and fire.
We suggest to check regularly the cable of the equipment. If it should result
that the cable is damaged or deteriorated, disconnect the equipment and do
not use it and let the cable be replaced with an original replacement part by
an authorised technician.
Protect the cable in such a way as to prevent twisting or interlacement with
other cables, trample on, crushing, stretching.
A wrong installation could cause damages to people, animals or things, for
which the manufacturer cannot be deemed responsible.