Trouble Shooting
Symptom
Fluid discharged from exhaust outlet
Air bubbles in fluid discharge.
Motor blows air out main exhaust when stalled
on either stroke.
Low fluid output volume.
Possible Cause
Ruptured Diaphragm (20)
Diaphragm Nut loose (4A)
Leak in suction side plumbing
Leak at Inlet Collar (4C)
Leak at Diaphragm Nut (4A)
U-cups inserted incorrectly, damaged, or
missing.
Ceramic valves damaged or contaminated
with debris (7).
Pilot valve not correctly oriented.
Low or blocked incoming air supply.
Outlet plumbing blockage.
Pump not primed.
Suction pipe too small or suction hose not
rigid (kinks or collapses).
Leak in inlet suction plumbing.
Pump blocked internally with debris.
* Add a a medium grade thread locking compound to the diaphragm rod threads.
10
Repair
Replace Diaphragm (20)
Tighten loose Diaphragm Nut (4A)*
Check connections of suction plumbing.
Check torque of Inlet Collar (4C)
Check torque of Diaphragm Nut (4A)
Check (2B & 2D) U-cups on major valve
spool.
Check (7) ceramic valves for debris or
damage.
Be certain to load the pilot valve in the
proper orientation per diagram found within
the center-body.
Check air supply.
Check for any obstruction in the outlet
plumbing.
The pump must be mounted vertically for
checks to properly work.
Check for pump cavitation - the suction
pipe should be sized at least as large as
the inlet thread diameter. The suction hose
must be rigid or non-collapsible.
Check all inlet plumbing for possible
suction leaks.
Inspect the pump for debris that could
block internal flow or foul checks.