6 - ADVANCED PROGRAMMING MODE
6600 / 6665
REGENERATION TYPE (7)
Press the
button . This display is identified by the number "7". This option is used to set the regeneration
type. There are several possible option settings:
- Timeclock: the electronics determines that regeneration is required when the set regeneration time has been
reached. The regeneration day override setting (see point 2.10) determines the number of days between two
regenerations.
- Meter immediate: the electronics determines that a regeneration is required when the available volume of
softened water drops to zero. The regeneration begins immediately.
- Meter delayed: the electronics determines that a regeneration is required when the available volume of
softened water drops to the reserve capacity. The regeneration begins immediately at the set regeneration
time only when the service flow has not been detected. With service flow, the regeneration will be delayed
in two 10 minute sections. After then if there is always a flow, the regeneration begins immediately. There
will be not a delay if the reserve capacity is zero.
- Meter delayed variable brining: Only available for UF valve.
The electronics displays and initiates regeneration as in meter delayed mode. In variable brining mode the first
cycle is brine refill, and second one is vacancy. All other cycles follow standard order. Electronic calculates first
cycle duration considering previous water usage and uses setting 7r, 7d & 7b.
- Meter Immediate with vacation mode (6 cycles mode): only available for UF valve.
The electronics displays and initiates regeneration as in meter immediate mode. However the electronics
requires a day override setting. However a day override setting is required and cycles sequence is different. The
regeneration cycles are following: brine draw, vacancy, slow rinse, backwash, rapid rinse, brine refill. The valve
will stay in vacancy if there hasn't been any consumption between the 2 last regenerations. The electronics will
switch to the next cycle if flow usage is detected.
Note: for the following options, please contact our technical support.
- Sensor immediate regeneration
- Sensor delayed regeneration
VOLUME OF RESIN (7r)
Press the
button. This display is available only with variable brining mode. This display is identified by "7r".
This parameter is used to set volume of resine.
SALT SETTING (7d)
Press the
button. This display is available only with variable brining mode. This display is identified by
"7d". This parameter is used to set salt ratio.
BLFC SIIZE (7b)
Press the
button. This display is available only with variable brining mode. This display is identified by
"7b". This parameter is used to set the BLFC size.
6600 – 6665 – 6700 – 6765
[7 - - - - - 1]
[7 - - - - - 2]
[7 - - - - - 3]
[7 - - - - - 4]
[7 - - - - - 7]
[7 - - - - - 5]
[7 - - - - - 6]
[7r - - 15.0]
[7d - - 120]
[7b - - 0.25]