Ribind S1 Manual De Instrucciones página 22

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

G
POINT A -
ELECTRIC CONNECTIONS
B
S3
J5
TR1
TR2
J4
SW
S1
J3
J2
J1
NC: NORMALLY CLOSED CONTACT
NO: NORMALLY OPEN CONTACT
POINT B - SETTINGS
DIP 1
MOTOR ROTATION DIRECTION CHECK (See Point C)
DIP 2
PROGRAMMING (See Point D)
DIP 1-2 STORAGE/DELETION OF RADIO CODES FOR COMPLETE OPENING (DIP 1 ON
followed by DIP 2 ON) (POINT F) ONLY FOR CRX MODELS
DIP 1-3 STORAGE/DELETION OF RADIO CODES FOR PEDESTRIAN OPENING (DIP 1
ON followed by DIP 3 ON) (POINT G) ONLY FOR CRX MODELS
DIP 2-1 PROGRAMMING OF PEDESTRIAN OPENING (See Point E)
DIP 3
ON
- Automatic Closing ENABLED
OFF
- Automatic Closing DISABLED
DIP 4
ON
- Radio receiver STEP BY STEP
OFF
- Radio receiver AUTOMATIC
DIP 5
ON
- STEP BY STEP
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
OFF
- AUTOMATIC
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
DIP 6
ON
- Photocells active only in closing
OFF
- Photocells always active
DIP 7
ON
- Encoder enabled for PLUS operator
J7
J6
SW
RADIO
RADIO
J8
SW1
SW2
SW3
J1
L1 - N
230Vac 50/60Hz POWER SUPPLY (120Vac/60Hz UPON REQUEST)
BLINKER (40 W MAX.)
J2
U
MOTOR COMMON CONNECTION
V-W
MOTOR PHASES AND CAPACITOR CONNECTIONS
J3
PED. BUTT.
PEDESTRIAN OPENING CONTACT (NO)
A+ TEST
+24Vdc SAFETY STRIP SELF-TEST POWER SUPPLY
LSC
CLOSE LIMIT SWITCH THAT CUTS OFF THE MOTOR IN CLOSING
COM
LIMIT SWITCH COMMON CONTACT
LSO
OPEN LIMIT SWITCH THAT CUTS OFF THE MOTOR IN OPENING
J4
STOP
STOP CONTACT (NC)
OPEN
OPENING CONTACT (NC)
CLOSE
CLOSING CONTACT (NC)
K. BUTT.
SINGLE PULSE CONTACT (NO)
A+
ACCESSORIES POWER SUPPLY +24Vdc
A-
ACCESSORIES POWER SUPPLY -24Vdc
SIGNAL
GATE OPEN INDICATOR 24Vdc
COM
COMMON CONTACT (common line for all the command and safety
inputs)
EDGE NC
SAFETY STRIP CONTACT (NC)
J5
AERIAL
RADIO ANTENNA
COM
COMMON CONTACT (common line for all the command and safety
inputs)
PHOTO NC
PHOTOCELLS CONTACT (NC)
J6
PROBE
Temperature sensor cable connection PROBE (Code ACG4665 optional)
J7
ENCODER
ENCODER connection (K PLUS operators)
J8
RADIO
CONNECTOR FOR EXTERNAL RADIO RECEIVER 24Vdc
S3
PROG.
PROGRAMMING BUTTON
TR1
LOW SPEED
ELECTRONIC REGULATOR FOR LOW SPEED ON APPROACH
TR2
TORQUE
ELECTRONIC TORQUE REGULATOR
SW
(only CRX control board) DO NOT REMOVE ANY JUMPER!
RADIO
OTHERWISE THE OPERATOR WILL NOT WORK!
SW S1
DO NOT REMOVE THE JUMPER! OTHERWISE THE OPERATOR WILL
NOT WORK!
SW1
DIP-SWITCHES
SW2
SW3
OFF
- Encoder disabled
DIP 8
ON
- Blinker pre-flashing
OFF
- Blinker normal flashing
DIP 9
ON
- Low speed in approaching DISABLED
OFF
- Low speed in approaching ENABLED
DIP 10 ON
- Electronic brake ENABLED (HARD brake, only for FAST operators)
OFF
- Electronic brake DISABLED (SOFT brake, only for FAST operators)
DIP 11 ON
- Gradual start ENABLED
OFF
- Gradual start DISABLED
DIP 12 ON
- Safety strip self test ENABLED
OFF
- Safety strip self test DISABLED
DIP 13 ON
- Motor operation control by external power relays (only for S1/R2 and
S1/R4 control boards). Encoder, low speed in approaching, gradual
start and electronic brake features, low speed and torque regulator will
be automatically disabled regardless their dip-switches and trimmers
position.
OFF
- Standard motor operation control without power relays
DIP 14 - selection of motor-type (see chart)
DIP 15 - selection of motor-type (see chart)
DIP 16 - selection of motor-type (see chart)
22
Tabla de contenido
loading

Este manual también es adecuado para:

S1-crxAbs1000Ac07097Abs1001Ac07096

Tabla de contenido