Optimization
To calculate the advance switch-on time required to reach the desired
temperature at the set time, considering the system thermal inertia. Optimization
takes place only at the first switch-on of the day, i.e.: the first programmed
passage from a temperature to a higher one.
Max. optimization duration
To set the max. duration (expressed in hours) of the advance switch-on time
calculated by optimization.
Pump anti-seizure
To turn the system on for 1 minute a day (h 23.58), thereby operating the water
circulation pump and preventing it from seizing. This takes place only if the
system has never been turned on during the day.
ENGLISH
Low Battery
To determine the relay status when batteries are flat for over 15 days. If this
parameter is excluded (---), the chronothermostat will keep on controlling the relay
as required by regulation until the remaining battery charge allows for it.
Baud
This parameter is not available