jbc CV-E Manual Del Usuario página 15

Ocultar thumbs Ver también para CV-E:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Maintenance
Before carrying out maintenance, always allow the equipment to cool.
- Clean the station screen with a glass cleaner
or a damp cloth.
- Use a damp cloth to clean the casing and
the tool. Alcohol can only be used when
cleaning the metal parts.
- Periodically check that the metal parts of
the tool and stand are clean so that the
station can detect the tool status.
- Maintain tip surface clean and tinned prior
to storage in order to avoid tip oxidation.
Rusty and dirty surfaces reduce heat
transfer to the solder joint.
- Periodically check all cables and tubes.
- Replace a blown fuse as follows:
1. Pull off the fuse holder and remove the
fuse. If necessary use a tool to lever it off.
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
w w w.jbctools.com
Clean
periodically
2. Insert the new fuse into the holder
and return it to the station.
15
Tabla de contenido
loading

Este manual también es adecuado para:

Ca-eCa-1eCa-2eCa-9e

Tabla de contenido