Control Panel - Powersoft Duecanali Serie Guia Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
LED Charts
LED Bars, signal metering
Color
Signal Metering
Clipping
ORANGE
*DSP+D User Limiter
YELLOW
-6dB
GREEN
-12dB
GREEN
-24dB
GREEN
-60dB
GREEN
RED
Red LED lights on in case of any kind of channel fault that prevents the normal channel operating.
1
Lighting
Timings
100 ms ON
FLASHING
900 ms OFF
500 ms ON
BLINKING
500 ms OFF
LED Bar, system status
Color
Name
Lightning
FLASHING
ORANGE
LIMIT
YELLOW
TEMP
ORANGE
CHECK
FAST BLINKING
GREEN
REMOTE
GREEN
POWER ON
GREEN
MAINS
FLASHING
FAST BLINKING
RED
ALARM
Red LED lights on in case of any kind of PSU fault that prevents normal operating.
1
Lighting
Timings
100 ms ON
FLASHING
400 ms OFF
100 ms ON
FAST BLINKING
100 ms OFF
500 ms ON
BLINKING
500 ms OFF
Operating mode LEDs
Color
Name
GREEN
POWER ON
ORANGE
STANDBY
ORANGE
AUTO STANDBY
ORANGE
ERROR CODE
8
Warnings
Lighting
Description
Thermal warning
SOLID ON
Thermal protection engaged
FLASHING
Auto Standby
SOLID ON
Signal presence
BLINKING
Channel muted
SOLID ON
Channel ready
SOLID ON
Channel fault
Description
9
Warnings
Description
Breaker Save Enabled
SOLID ON
Breaker Save limiting power draw
Thermal warning
SOLID ON
Thermal protection engaged
SOLID ON
System self checking
BLINKING
Self check completed
Self Check Unavailable
SOLID ON
Connected to Armonía Pro Audio
Not connected to Armonía Pro
OFF
Audio
SOLID ON
System ready
OFF
System off
AC mains voltage within the
SOLID ON
operating range
OFF
Undervoltage
Over/Undervoltage Warning
Overvoltage
BLINKING
Mains FUSES blown
PSU fault
SOLID ON
OR Critical Faults
Description
1
Operating mode
Standby
SOLID ON
BLINKING
BLINK COUNTER

Control Panel

Label
Label
2
POWER
3
CALL
SOFT
4
RESET
HARD
5
RESET
6
CHECK
CH1
7
CH2
The push-buttons are disabled when connected to Armonía.
1. Keep pressed both the SOFT RESET button and the HARD RESET button for at least 3
1
seconds to completely reset the amplifier to its factory default configuration (this won't
delete any preset stored in the internal memory).
2. The potentiometer is in series with the remote level control so it can be used to limit the
output volume regardless to any remote adjustment.
* Press again to resume normal operations
Self Check
1
Power On
SOLID ON
1. An 8Ω dummy load is needed to measure the output current. If the dummy
load is not applied the system reports a fault.
Type
Action
keep pressed for
Pushbutton
3 seconds
Pushbutton
press
keep pressed for
Pushbutton
3 seconds
1
keep pressed for
Pushbutton
3 seconds
1
keep pressed for
Pushbutton
3 seconds
turn
Potentiometer
2
counter-clockwise
turn
Potentiometer
2
counter-clockwise
System OK.
Power supply fault
AC Mains voltage
out of range
(over/under voltage)
PSU temperature
out of range
Fan Error
Channel#
Output Waveform
non-conformity
Channel#
Temperature
out of range
Channel#
Output current measurement
non-conformity
Description
Toggle
system ready/standby mode
Highlight the amplifier in the
Armonía workspace
Reset network parameters to
factory default
Reboot the system
Duecanali
1604
Start the self-checking
procedure*
Attenuate the output level of
the signal on channel 1
Attenuate the output level of
Duecanali
the signal on channel 2
1604
Duecanali
1604
6
Duecanali
1604
Duecanali
1604
Duecanali
1604
Duecanali
1604
Duecanali
1604
1
Tabla de contenido
loading

Tabla de contenido