12. ELECTRICAL CONNECTIONS

The electrical installation should be done by qualified professionals, keeping in mind the following
points:
Connect the equipment following the wiring diagram included in this manual.
Place a U-curve thermal-magnetic circuit breaker in the general power connection to
protect the line in the case of a short in the circuit.
Place a differential circuit breaker in the general power connection to protect the
equipment from possible grounding problems. The differential breaker should be minimum
30 mA.
Differential circuit breaker.
Circuit breakers or thermal-magnetic circuit breaker.
The picture shown below is a diagram of how the connections should be made.
Before installing the connections, be sure to disconnect the electricity so that the power supply is
turned off.
Connect the power supply wires to the machine's input terminal.
Connect the grounding wire to its corresponding terminal.
All local and national electricity codes concerning the protection of defects in electric
power lines should be respected at all times during the electrical installation.
Verify the torque of all electrical connections.
The electrical resistance between the ground and any electric terminal will be verified to be
over 1 megaohm.
In the case of fluctuations in the power supply, a power supply stabilising system is
recommended in order to protect the equipment.
ADVISE: Heating Pump must not work if the cleaning pump it is not working. Avoid
installing delays that could lead to these situations. Do not modify the motor protections. In
case of any doubt contact the installer.