Acoustic Signals; Programming Procedure - RIB NO TOUCH 868 Serie Manual Del Usuario

Fotocélula vertical sin cables de la costa para prevenir impactos en las puertas seccionales y puertas enrollables
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

PROGRAMMING MASTER NO TOUCH 868 AND PHOTOCELLS NO TOUCH 868
A -
SETUP AND VERIFY THE CORRECT OPERATION OF THE NO TOUCH 868
PHOTOCELL
- The correct operation of the TX NO TOUCH 868 is signalled by the green DL6 which turns
on for 10 seconds after the insertion of the 3,6V battery.
- Press and release the S2 PROG pushbutton on the RX NO TOUCH 868 (the photocell is
activated for 3 minutes to check the alignment)
If the photocells are correctly aligned the red LED DL5 will remain turned on.
- During the 3 minutes the red LED DL5 stays on, check that when inserting an obstacle,
the red LED DL5 turns off and simultaneously the bi-colour LED DL1 on the MASTER NO
TOUCH 868 turns green for the time the obstacle is inserted.
- On the MASTER NO TOUCH 868, the LED DL3 must also turn off indicating the correct
exchange of the contact on the strip or the photocell input of the control panel has
occurred.
If the red LED DL5 stays off, check;
- that supports are fixed correctly;
- that on the TX NO TOUCH the position of the jumper JP4 which controls the infrared
signal range:
- is positioned on L and set to a range of 5 metres.
- is positioned on H and is set to a range of 10 metres.
B -
POWER UP MASTER NO TOUCH 868 SUPPLY
After making all connections, supply the control panel with MASTER NO TOUCH 868.
The yellow LED DL2 should be on and the buzzer should emit a sound to signal correct
power supply.
C -

PROGRAMMING PROCEDURE

Insert the batteries into the NO TOUCH circuits and position them in the internal container
already fixed to the edge of the door.
To run the set up perform the following procedure:
- Press the S1 PROG RX pushbutton which is found on the MASTER NO TOUCH 868 => the
bi-colour LED DL1 will flash red for 1 minute (time to run set up)
- Press the S2 PROG pushbutton on the safety RX NO TOUCH 868.
- On the MASTER NO TOUCH 868 the bi-colour LED DL1 changes from red to green and a
buzzer tone signals the correct security set up. At the same time the LEDs DL3 and DL4
turn on and the control panel receives the correct safety devices signals.

ACOUSTIC SIGNALS

MASTER NO TOUCH 868 has a buzzer which signals in the installation phases and the
warning status when batteries are almost dead or alarm status in the event of failure of
one of the devices.
D -
ACCELEROMETER
The ACCELEROMETER is not compatible with automated systems equipped with
gradual start or very slow.
Stop the gradual start function or, if not possible, deactivate the ACCELEROMETER. If
the door is very slow deactivate the ACCELEROMETER.
- Verify a functional check of the installed photocell by activating the automation movement
and checking that when inserting an obstacle, in the closing door, it stops and reverses
the motion.
- In the event the door stops after starting and the alarm signals 5 BUZZER tones, this means
that the movement of the door was not detected by the ACCELEROMETER (caused by the
gradual start or by the door very slow), therefore for the correct operation of the door,
it is necessary to exclude the ACCELEROMETER.
To deactivate the ACCELEROMETER you need to:
- move the JP3 jumper on the RX NO TOUCH 868 to OFF;
- press the S2 PROG pushbutton;
- the buzzer on board the MASTER NO TOUCH 868 will emit a tone for 3 seconds, signalling
successful deactivation of the ACCELEROMETER.
ACTIVATING THE ACCELEROMETER
To activate the accelerometer you need to:
- move the JP3 jumper on the RX NO TOUCH 868 to ON;
- press the S2 PROG pushbutton;
- the buzzer on board the MASTER NO TOUCH 868 will emit a tone for 3 seconds, signalling
successful activation of the ACCELEROMETER.
VERIFY THE CORRECT OPERATION OF THE ACCELEROMETER
- With ACCELEROMETER ACTIVE (jumper JP3 ON on the RX NO TOUCH 868) verify that
when moving the NO TOUCH 868 RECEIVER the LED DL1 turns on fixed red, the BUZZER
emits 4 tones and the LEDs DL3 and DL4 turn off for 5 seconds.
- After 5 seconds the DL1 LED will turn off and DL3-DL4 will turn on.
E -
TIME SET UP (ONLY WITH ACCELEROMETER ACTIVE - JP3 ON)
WITH THE ACCELEROMETER ACTIVE THE NECESSARY TIME STORAGE PROCEDURE IS
PERFORMED.
IF THIS PROCEDURE IS NOT MADE, IT IS POSSIBLE THAT AFTER THE DOOR STARTS,
THIS STOPS AND 5 BUZZER TONES ARE EMITTED.
- Press the S1 PROG RX pushbutton on the MASTER NO TOUCH 868, the LED DL1 will
flash green.
- Control the door to open and close it completely at least two times consecutively.
- Wait for the green LED DL1 to turn off, or alternatively press the S1 pushbutton once to
end the procedure.
F -
SETTING UP PEDESTRIAN DOOR SECURITY (RED transmitter code
ACG6202)
It is possible to set security for the pedestrian door only if you have already programmed the
NO TOUCH 868 photocell.
This security is the RED transmitter which monitors a NC contact (not supplied) installed on
the pedestrian door on the main door.
To run the set up perform the following procedure:
- position the dip switch n° 2 to ON (COMPULSORY);
- supply the RED transmitter through the batteries;
- press the S1 PROG. RX pushbutton which is found on the MASTER NO TOUCH 868: the
bi-colour LED DL1 will turn green and flash for 1 minute (time used to run set up)
- press the S2 PROG. TX pushbutton the RED transmitter: on the MASTER NO TOUCH 868
the bi-colour LED DL1 will stop flashing green and turn off . The buzzer will emit a tone
31
G
B
Tabla de contenido
loading

Este manual también es adecuado para:

Ad00316Acg8048Acg6154No touch 868Set no touch 868

Tabla de contenido