RIB NO TOUCH 868 Serie Manual Del Usuario página 27

Fotocélula vertical sin cables de la costa para prevenir impactos en las puertas seccionales y puertas enrollables
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

MASTER NO TOUCH 868 CONNECTIONS TO A CONTROL PANEL WITH AN OUTPUT TO SUPPLY A BLINKER
WARNING: MASTER NO TOUCH 868 performs the inspections required by EN 12978 par. 4.1 to the final positions of the run only if the AUTOTEST function is available. IT'S
NECESSARY THAT THE CONTROL PANEL WHERE THE MASTER NO TOUCH 868 IS APPLIED, HAS THE AUTOTEST FUNCTION.
WARNING: INSERT MASTER NO TOUCH 868 IN A SHELTERED CONTAINER. The use of the product inside metal containers can generate a system malfunction. It is therefore
advised, for a perfect reception/transmission of the signals to add the antenna, code ACG5451, which should be applied externally to the container and connected
to the J3 terminal of the MASTER NO TOUCH 868.
WARNING: It is advisable to activate the function PRE-BLINKING on the electronic control panel, if available.
WARNING: Verify the presence of the protection against short circuits on the control panel through fuses connected in series to the second supply. In the event it is not present,
connect in series to the supply with a time-delay fuse (T) of 200 mA. Disconnect power to the automation control panel before making the connections to the MASTER
NO TOUCH.
Connect the terminal COM on the electronic
Connect the input STRIP on the electronic control panel. If not
available use the PHOTOCELL input
!
*
COMPULSORY connection for electronic control panel with 120/230V
50/60Hz blinker output
**
COMPULSORY connection for the electronic control panel with
12/24V
blinker output. WARNING: RESPECT THE POLARITY AS
INDICATED ON THE PRINTED CIRCUIT.
WARNING: The connection of the blinker output of the control panel to the
terminals J2 or J4 of the MASTER NO TOUCH is obligatory even in the event a
flashing light is not present on the installation.
If the connection fails the door does not work and the buzzer emits 4 warning
tones of connection failure.
INPUT COM
Common terminal of CONTACT NC and ALARM NC.
WARNING: The COM terminal is required to connect the COMMON to the control panel.
In the event that COM is not connected, the system alarm will signal and the buzzer will
sound 2 tones.
INPUT CONTACT N.C.
CONTACT NC terminal: is to be connected to the STRIP or PHOTOCELL output of the
electronic control panel.
WARNING: Remove any jumper, replacing the STRIP or PHOTCELL NC contact, from the
terminals of the electronic control panel.
control panel
Power Supply
12/24V
Connect the AUTOTEST output on the
electronic control panel
27
!
*
120/230V 50/60Hz
Connect the STOP input on the electronic control panel or other
input which stops the movement of the motor
INPUT ALARM N.C.
ALARM NC feed terminal: it is dedicated to the series connection of the STOP
command on the electronic control panel. In the event that the STOP input is not present,
connect the ALARM NC contact in series to an input which allows the electronic control
panel to be blocked.
WARNING: Remove any jumper, replacing the STOP NC contact, from the terminals of the
electronic control panel.
CONNECTING AUTOTEST INPUT (for complying with the standard EN 13849-1:2015)
If the panel is not equipped with AUTOTEST, the control test is ignored.
- If the panel is equipped with AUTOTEST, position the jumper JP1 of the MASTER NO
TOUCH 868 according to the power supply given by the control panel used, adhering to
its manual.
- Connect the AUTOTEST output of the control panel to the AUTOTEST terminal of the
MASTER NO TOUCH 868 so as to control the system at the end of each complete opening
or at the start of the closing operation of the automation.
- Closing will occur only if the MASTER NO TOUCH 868 has passed the control test.
- If the check of the MASTER NO TOUCH 868 has failed, the control panel blocks the
automation and DL3 and DL4 LEDs on the MASTER NO TOUCH 868 will turn off. The
buzzer emits 2 tones and the bi-colour LED DL1 will flash red-green, signalling an anomaly.
To restore the functioning:
- check the AUTOTEST connections and the position of the JP1 jumper;
- press the S1 PROG RX pushbutton on the MASTER NO TOUCH 868;
- the LEDs DL3 and DL4 will turn on.
The MASTER NO TOUCH 868 is ready for a new AUTOTEST.
G
B
-
!
**
+
12/24V
Tabla de contenido
loading

Este manual también es adecuado para:

Ad00316Acg8048Acg6154No touch 868Set no touch 868

Tabla de contenido