Maintenance Schedule - Campbell Hausfeld GN0950 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Operating Instructions
Maintenance
compression cycle, and the intake
and exhaust valves are closed. (The
piston pushes a small amount of air
from the spark plug hole on
compression).
6. To clean air filter –
Remove filter
from generator.
Wash in a solvent.
Pour motor oil
(SAE #20)
on filter,
squeeze
out excess
and reinstall in
generator.
R
B
0
0
Engine stop switch
OFF/ON
Br
Br
W/R
B
Wiring diagram for GN0800
7. To clean fuel filter – Stop
(Continued)
engine. Turn fuel switch
to closed (horizontal)
position. Remove fuel
filter and
disassemble.
Item
Spark Plug
Air Filter
Fuel Filter
Decarbonization Remove carbon deposits
AC receptacle
AC circuit breaker
3A (2A)
24 µ F/250VAC (10µF/300VAC)
B
= Black
R
= Red
G
= Green
Br = Brown
O
= Orange
G/Y = Green/Yellow
B/W= Black/White
B
Ignition coil
0
G/Y

MAINTENANCE SCHEDULE

Action
Remove carbon
Adjust gap
Replace if necessary
Clean
Replace if necessary
Clean
Replace if necessary
Check and adjust at
your dealer
G/Y
R
Br
G/Y
Oil sensor
B
B/W
T.C.I. unit
4
Wash filter in a
solvent. Dry with a
clean cloth. Reinstall
in generator.
Every 50 hours
or every month
G
G/Y
AC protector
R
10A (6.5A)
Output light
G
G
B
= Black
R
= Red
G
= Green
Br = Brown
G/Y = Green/Yellow
B/W= Black/White
1
Oil pilot light
Y
2
B/W
3
OFF/ON
4
Engine stop switch
Wiring diagram for GN0950
Every 150 hours
or every 3 months
G
G
G
AC receptacle
220V
220V
Capacitor
24 µ F/300VAC
G/Y
Tabla de contenido
loading

Este manual también es adecuado para:

Gn0800

Tabla de contenido