6) What to do if...
a small troubleshooting guide!
No transmitter commands are executed, immediately after
powering up the control unit, and the LEDs do not flash.
Check that the control unit is correctly powered: there must be
mains voltage present between terminals 5-6. If power supply is cor-
rect, there is probably a serious fault and the control unit must be
replaced.
The Step-by-step pushbutton does not activate the
manoeuvre when pressed.
Check the electrical connection of the pushbutton: there must only
be supply voltage on the pushbutton input (between terminal 4 and
6) when the pushbutton is pressed.
After a radio command, the LED emits 6 short flashes and
no manoeuvre is executed.
Transmitter timing is out of phase; the transmitter memorisation pro-
cedure must be repeated.
After a command the LED emits 10 flashes and then the
manoeuvre is executed.
The memorised parameter self-test procedure has detected a fault.
In this case, the entire memory must be cleared, and all transmitter
memorisation and programming procedures must be repeated.

7) Technical specifications

Note. All technical specifications refer to a temperature of 20 °C.
SRCR 140 A control unit
Power supply
Maximum motor power
Operating temperature
Dimensions / weight
Protection rating
Manoeuvre duration
Radio receiver
Frequency
Code
No. of memorisable transmitters
Transmitter range
(*) The transmitter range is strongly influenced by other devices operating at the same frequency with continuous transmission, such as alarms
and radio headphones which interfere with the control unit receiver.
Subject to change without prior notification.
We hereby declare that this device conforms to the fundamental requirements and relevant provisions of the CE directives.
Declaration of conformity: www.stobag.com
www.stobag.com
The motor is stationary, but at times the Step-by-step com-
mand needs to be given twice to start operation.
The programmed work time may be excessively long with respect to
the effective duration of the manoeuvre. Although the motor is sta-
tionary at a limit switch, the control unit may consider the motor still in
movement from a previous command. In this case the first command
is interpreted as a Stop and the second as a movement command.
To eliminate this problem, ensure correct programming of the work
time (paragraph 4.2).
Transmitter memorisation not possible.
Check the number of LED flashes during the memorisation proce-
dure; 6 long flashes indicate that the memory is full; 2 flashes, with
the second longer than the first, indicate that the transmitter memo-
risation block is active.
120 or 230 Vac, 50/60 Hz, limits: 100÷255 Vac
500 VA for Vn = 230 V, 600 VA for Vn = 120 V
-20÷55 °C
40 x 18 x 32 / 20 g
IP20 (container intact)
150 s
433.92 MHz
fixed code, rolling code
30, including maximum 3 SKIROSOL SRCK 610 climatic sensors.
Estimated at 150 m in open space and 20 m inside buildings (*)