2.4.1. POSSIBLE FAILURES AND THEIR ELIMINATION

Warning! : Only technically qualified service centres can perform the operations
described below!
Warning! : Before resetting the safety thermostat, it is always necessary to
eliminate the problem causing its activation!
Even a normal use of the appliance may cause operation inconveniences and
failures.
The most common problems are the following:
P
AN DOES NOT REACH SET TEMPERATURE
Possible causes:
- Check connections to the switch.
- Check connection to the working thermostat.
- Check connection to electromagnetic switch.
- Heating elements are burned.
S
IGNAL LAMPS DO NOT LIGHT UP
- Check the connection to the switch.
- Signal lamp is faulty.
THE BRATT PAN WORKS WITH DISCONNECTED THEMOSTAT
- Electromagnetic switch contacts are cut off.
L
OW EFFICIENTY OF THE PAN
- Check the heating elements.