Operation; Preparing For Start-Up - VWR VP 8 Vac Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

English
When using a coolant valve:
Danger of the high performance condenser bursting
 Make sure that the coolant valve is mounted between
the coolant supply and the coolant inlet port of high
performance condenser.
WARNING
Electrical connection of the pump
 Insert the plug of the pump into the socket of the operating unit (see
fig. 4/5, page 8).
Electrical connection of the system
 Connect the operating unit (see fig. 4/5, page 8) to a properly
installed safety socket.
7.

Operation

7.1

Preparing for Start-up

Before switching on the pump/the system, observe the following points:
Operational requirements
Pump
All hoses attached properly
Pump/
Fan openings not blocked
System
Specifications of the power supply correspond with the data on the pump's/the vacuum
system's type plate
The pump outlet is not closed or constricted
Vapor outlet on the top of the high performance condenser is not blocked
The media are compatible with each other (when running two different proccesses
simultaneously)
No reactive, explosive or otherwise hazardous mixtures may be produced when ventilating
the vacuum system through the air inlet (see fig. 4/9, page 8. If necessary, use an inert
gas).
System
Clamp connections are tight
All cables attached properly
Tab. 4
7.2
Starting
 Only operate the pump/the system under the operating parameters and conditions described in chapter
4, Technical data.
 Make sure the pump/the system is used properly (see chapter 2.1).
 Make sure the pump/the system is not used improperly (see chapter 2.2).
 Observe the safety precautions (see chapter 3).
Hazard of the pump head bursting due to excessive pressure increase
 Do not exceed max. permissible operating pressure (see chapter 4).
 Monitor pressure during operation.
 If the pressure exceeds the maximum permissible operating pressure, immediately shut
WARNING
down pump and eliminate fault (see chapter 9. Troubleshooting).
 Only throttle or regulate the air or gas quantity in the suction line to prevent the maximum
permissible operating pressure from being exceeded.
 If the air or gas quantity in the pressure line is throttled or regulated, make sure that the
maximum permissible operating pressure of the pump is not exceeded.
10
Fig. 5: Coolant supply of high
performance condenser
1 Coolant inlet
2 Coolant outlet