G
B
TECHNICAL DATA / INSTALLATION JOLLY ONE
TECHNICAL DATA
Max gate weight
Max gate surface
Limit switch winding capacity
Nominal functioning torque
Max operating torque
Max lifting force from earth
Max operating force
Pulley revolutions
Pulley diameter
Shaft diameter
EEC Power supply
Motor capacity with load
Power absorbed with load
Capacitor
Functioning cycles
Daily operations suggested
Service
Nominal functioning time
Motor weight
Working Temperature
Protection
R
OLLING GATE CONTROL
The European Standard EN 12604 "Industrial, Commercial and Garage Doors and
Gates - Mechanical Aspects - Requirements", at the point 4.3. "Protection against
unintentional and uncontrolled movements" requires also that*:
a - The vertically operating door leaves shall be balanced so that the door
leaf can stop in any position, or that the out-of-balance state shall not
produce, in any case, a static force at the primary closing edge of the
door exceeding 150N (15,3 kg / 33,70 lbs). Verify it after having manually
released JOLLY ONE operator.
b - If a spring fails, the resulting out-of-balance static force occurring at the
primary closing edge of the roller shutter shall not exceed 200N (20,4 kg /
44,94 lbs), even when JOLLY ONE operator is manually released. After this
failure, you must intervene on the door to substitute the broken spring
and correct the balance state. Therefore, we suggest you to fraction the
roller shutter weight with an adequate number of springs (*This is a free
interpretation).
WARNING: The EN 12445 standard ´Industrial, commercial and garage doors
and gates - safety in use of power operated doors - test methods´ at point
4.1.2 ´safeguarding against hazard of being lifted´ provides that the rolling
gate shall not be able to lift more than 20 kg/44lbs.
In order to meet this standard, RIB suggests to install the control board with
electric power regulation J-CRX (cod. ABJ7080).
373,5 / 14,7
Measurements in mm/in
kg/lbs
2
m
N°rotat.
Nm
Nm
kg/lbs
kg/lbs
rpm
mm
200/7,9 - 220/8,67 with adapter ACJ9055
mm
60/2,3 - 42/1,64 with adapter ACJ9040 - 48/1,9 with adapter ACJ9050
W
A
µF
N°
N°
s
kg
°C
IP
PARTS TO INSTALL MEETING THE EN 12453 STANDARD
COMMAND TYPE
(out of a public area*)
with manned operation
with visible impulses
(e.g. sensor)
with not visible impulses
(e.g. remote control device)
automatic
* a typical example are those shutters which do not have access to any public way.
A: C ommand button with manned operation (that is, operating as long as activated),
like code ACG2012.
B: Key selector with manned operation, like code ACG1010.
C: Motor force regulation.
D: S afety edges or Sensor able to detect an obstacle and/or other safety devices to
keep thrust force within the limits of EN12453 regulation - Appendix A.
E: P hotoelectric cells, eg. code ACG8026 (To apply on the whole height of the door
up to max 2,5 m as indicated on EN 12445 point 7.3.2.2).
I
N ORDER TO ENSURE A CORRECT FUNCTION ONLY
RIB'S COMPONENTS MUST BE USED
1 - JOLLY ONE operator
2 - Photoelectric cells (external)
3 - Push-Button
22
22
22
22
JOLLY ONE
220 / 485
16
8,5
150
110
150 / 330
110 / 242
10,4 (50Hz) - 13,4 (60Hz)
230V ~ 50-60Hz
570 (50Hz) - 550 (60Hz)
2,7 (50Hz) - 2,6 (60Hz)
20
5 - 20s/2s
20
30%
240
9,5
-10 ÷ +55
30
USE OF THE SHUTTER
Skilled persons
Skilled persons
(public area)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
4 - Key selector
5 - Tuned aerial
6 - Flashing lamp
Unrestricted use
-
C and D, or E
C and D, or E
C and D, or E