Filter replacement
8 FILTER REPLACEMENT
8.1 Special safety instructions
WARNING: ELECTRICAL VOLTAGE!
Before you open the device, disconnect it from the power supply by unplugging the
power cord from the power outlet!
WARNING!
Wear personal protective equipment (PPE)!
Personnel responsible for changing filters are strongly advised to wear appropriate
personal protective equipment (PPE) and to follow safe work practices in accordance
with legal and industrial safety regulations.
Use an FFP2 mask, disposable gloves and protective goggles when replacing the filter
elements!
CAUTION!
Use only spare parts approved by the manufacturer!
CAUTION!
Risk of damage to the replacement filter due to careless transport!
Avoid damaging the filter medium (filter paper) by touching the plastic frame of the
filter elements only!
CAUTION!
Risk of damage through the use of unauthorized cleaned air filters!
Filters are not reusable!
Do not try to clean and reuse the filters. Attempting to clean filters using methods
such as compressed air can damage the filter and reduce filter efficiency.
NOTE
Dispose of the filters in accordance with statutory and local regulations.
You can generally dispose of used filters in an airtight plastic bag in the household
waste.
Contact your local waste disposal authority for further instructions on proper
disposal.
28 – EN
8.2 Filter replacement at a glance
Antiviral air purifier
Applies to models
with integrated
UV lamps
Applies to models
with integrated
UV lamps
10 cm
5 cm
100 cm
100 cm
Filter replacement
Control element (LED touchsreen) 1
Air inlet 2
Housing door 3
Clean air outlet 4
Side door locks (2x) 5
Power switch (inside the housing door) 6
Pre-filter element (ePM1 55%) 7
HEPA-filter element (H14) 8
Rear wall of the housing 9
UV-C light bulb (2x)* 10
Ligt bulb socket (2x)* 11
Integrated C20 power socket 12
Fan 13
Base 14
Pre-filter
HEPA Filter
*Applies to models with integrated UV lamps