Service Menu; Show The Remaining Filter Service Life; Confirm Filter Change; Display Operating Hours - MANN+HUMMEL OurAir SQ 2500 Manual De Instrucciones Original

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82
Operation
0
1250 m
3
/h
2500
Menu
Button
Back

7.9 Service menu

The service menu shows you the remaining service life of the filters and the operating hours of the
appliance.

7.9.1 Show the remaining filter service life

Note
You are automatically informed when the filter elements should be changed. Under
normal conditions of use, such as in offices, medical practices, schools and
environments with regular room cleaning, it is recommended to replace both the
prefilter and the HEPA filter at least every two years (if the filter replacement is not
already indicated in the LED display beforehand). An earlier end of service life (due to
improper use and increased contamination, for example) may be manifested by a
louder operating noise or unusual odor development, among other things. In these
cases, the prefilter must be replaced before the recommended service life has been
reached.
Menu
Button
Service menu
FILTER HEALTH
10 of
730 days

7.9.2 Confirm filter change

After replacing the filter (see chapter 8 on page 28) you can reset the filter change indicator as follows:
Menu
Button
Service menu
Change filter
26 – EN
Action
The appliance immediately accepts your entries.
The "Back" button takes you back to the "Advanced
settings" menu. The "Back" button takes you back
to the "Settings" menu.
Action
The "FILTER HEALTH" field displays the filter service
life and, if applicable, information about the need
for a filter change.
As an indicator, the display shows the number of
days while slowly changing from green to red.
Action
In the service menu, press the "Change filter"
button for at least 2 seconds.
The button changes to green and the message "OK"
is displayed.

7.9.3 Display operating hours

Menu
Button
0
1250 m
/h
2500
3
Service menu
Advanced settings
0
1250 m
/h
2500
3
Back

7.9.4 Confirm light-bulb replacement*

After replacing the UV-C light bulbs* (see chapter 9 on page 32) you can reset their operating hours
counter as follows:
Menu
Button
0
1250 m
3
/h
2500
Service menu
Advanced settings
Change UV light bulbs
0
1250 m
3
/h
2500
Confirm
Back

7.10 Display device information

Menu
Button
Device information
i
* Applies to models with integrated UV lamps
Operation
Action
In the service menu, tap the arrow to go to the
"Operating hours" view
The following values (in hours) are shown on the
display:
– Total operating hours
– UV operating hours
The "Back" button returns you to the "Service
menu" that displays the filter health.
Action
In the service menu, tap the arrow to go to the
"Operating hours" view.
In the operating-hours view, press the "Confirm"
button for at least 2 seconds.
The button changes to green and the message "OK"
is displayed.
The "Back" button returns you to the "Service
menu" that displays the filter health.
Action
The "Device information" menu shows you
information about the appliance along with contact
details for MANN+HUMMEL.
EN – 27