EN
A EX 2GD - Vacuum Cleaners
WARNING!
•
Only properly trained personnel are allowed to use this vacuum cleaner.
•
Do not use the compressed air hose to pull the vacuum cleaner. It can tip over.
•
Do not use the compressed air hose with a divided machine.
•
Make sure all modules, hoses, and cables are securely fastened before use. See figure 14
and figure 15.
•
Secure compressed air hose with a cotter pin and safety chain before use, see
figure 1(A).
•
Do not use if the ambient temperature exceeds 40°C.
•
Do not expose the body to vacuum inlets when operating the unit.
•
Always use proper protective equipment such as safety shoes and hearing protection.
•
Always use proper protective equipment where there is a risk for exposure to dust, see
figure 8.
•
Watch your head. The height of the frame is low.
•
For adjustable frame, do not make height adjustment when the silo is filled with
material.
CAUTION!
•
Use the correct filter for collecting wet material.
•
Turn off vacuum cleaner if liquid or foam escapes from it.
•
Make sure compressed air pressure is between 6 and 8 bar.
•
If wet material is to be vacuumed, use a float ball and filter designed for that purpose.
•
Make sure to correctly assemble the filter bag when changing from wet to dry collection.
NOTE!
•
Make sure the manual discharge valve is closed before starting the vacuum cleaner. It
cannot be accessed during operation.
•
The float ball can be removed when collecting dry material.
•
Clean the filter after each use.
•
When the filter is clogged or the pre-separator is full, suction power is reduced. Clean
the filter and empty the pre-separator. See Section 6 Maintenance.
•
For vacuuming wet material, when the container is full, the suction flow is shut off by the
float ball. Turn off the vacuum cleaner before emptying the container.
•
For best results, adjust the gulper head depending on the type and weight of material to
be vacuumed, see figure 6.
Turn on the vacuum cleaner as follows:
1.
Connect the compressed air hose to the ejector top. See figure
2.
Open ball valve on ejector top to start vacuuming, see figure
22
Risk of personal injury.
Risk of equipment damage.
.
1
(C).
1